Diagnosis data – Rockwell Automation SCD Operating Software User Manual

Page 12

Advertising
background image

SCD Operating Software User Manual

12

belong to the user group Machine operator. To be able to send
configurations, log in with the device or the device system as
Machine maintenance personnel or as Authorized client, using the
appropriate project password.

The factory-set password ABGM has been entered for the
user group Authorized client.

Note If a device cluster has been assembled using devices which

have already been configured, the individual devices may
have different passwords. In this case you will be asked for
your password separately for each device.
Once you have entered the correct passwords for all
devices, the password for the first device will be assigned to
all devices.

Change Project Password

The user group Authorized client can enter/change the passwords
for the user groups Machine maintenance personnel and
Authorized client. The passwords will be saved in the devices. This
allows the devices to be protected from being configured by
unauthorized persons.

Reset Password

If you have forgotten the password for a device, you can reset the
password. To do so, you need what is called a reset password. You
will get this password once you have identified yourself in writing to
the manufacturer.

For this purpose use the form Faxform.pdf on the SCD CD-ROM.
For the identification you will need the serial number of the device
and the number of the device counter (Device-counter-nr.). Both
numbers can be found in the Reset password dialog box.

Note When you reset the password for a device, it is configured

as on delivery! For operation to be possible you must re-
edit the configuration as delivered, or transfer a suitable
previously saved and verified configuration to the device.

Diagnosis Data

With the aid of the SCD you can perform diagnostics on devices
connected and linked to the SCD (or identified by the SCD). To do
so, load the diagnostics data to the viewing area of the monitor.

As soon as the diagnostics data is displayed, the standard menus of
the software will disappear. Then only the Project menu and the
related buttons are available. The navigation area of the SCD can
no longer be used.

ATTENTION: Change the Machine
operator user group!

If you leave the PC unattended when it is
connected to devices, you must change to the
Machine operator user group in order that no
unauthorized persons can transfer configurations
to the devices!

You can print and save the diagnostics data. You can also insert a
comment via an additional dialog box. This comment will also be
printed and saved.

The commands necessary to carry out the above-described
functions are found in the context menu of the devices under
Diagnostics. Please refer to the online help for a specific
description and detailed instructions.

Comments

You can add comments to the reports displayed in the viewing area
of the SCD. These comments are also printed with the appropriate
report and saved.

Advertising