4. Remove wire #13L1 from the side of Auxiliary
contact block K2. Move this wire up to the open side
of terminal 12L1 on the terminal strip TB-1.















5. Connect the blue air line hose to the air regulator at one end and to the gatefold plate at the
other end. The connections are brass quick connect couplings. It is best to do this without air
pressure in the line.





















6. Connect the airline from the air
regulator to the incoming air supply.
Note that (90) PSI or (5) bar is
required for the correct operation.