Baumfolder Gatefold User Manual

Page 5

Advertising
background image

7. Install the gatefold foldplate in the #4 foldplate
position. Make sure that there is no interference.
Turn the handwheel on the folder to check. If there
is interference use Baum gage kit #261-998-BG-
01 from the Baum Parts Department to set
clearances by adjusting the plate stops correctly.






8. Connect the power cord for the gatefold control
box to electrical connection X10 on the left-hand
side of the main folder control box. If the X10
connector is not on the main box, order part
number 263-564-01-00 from the Baumfolder Parts
Department. Contact the Baum technical support
department for correct wiring information.




9. Fasten the optical sheet sensor to the underneath
side of the #3 foldplate on a rib. Locate the sensor
all of the way forward against the front lower
support rail. Tighten the setscrew in the side. You
can use the long-handled 4mm-ball driver that is
standard with the folder to adjust the setscrew.







10. Connect the air supply and set the pressure
regulator to (5) bar on the gauge. Pull up on the
adjustment knob to make adjustments.

5