b) After  feeling  the  pressure  on  the  strip  of  paper  on  the  operator  side,  gently  pull  

on  the  strip  of  paper  on  the  non-­‐operator  side  and  feel  the  amount  of  pressure  
the  fold  rolls  are  applying.  

 

o If  pulling  on  this  strip  of  paper  fells  like  there  is  not  enough  pressure  and  does  

not  cause  the  fold  rolls  to  start  rotating,  turn  the  gapset  knob  counter-­‐clock  
wise  to  add  more  fold  roll  pressure.  
 

o If  pulling  on  this  strip  of  paper  fells  like  there  is  too  much  pressure  and  cause  

the  strip  of  paper  to  tear  rotating,  turn  the  gapset  knob  clock  wise  to  reduce  the  
amount  of  fold  roll  pressure.  

 

c) Now  that  you  have  initially  cailbrated  the  fold  roll  pressures  on  the  operator  and  

non-­‐operator  sides,  you  must  go  back  and  check  the  pressures  on  each  strip  of  
paper  again  to  ensure  the  pressures  remained  the  same.  You  may  have  to  
readjust  the  pressure  on  each  side  to  ensure  the  proper  amount  of  fold  roll  
pressure  is  maintained.  
 
During  calibration  of  the  fold  roll  pressure  settings,  it  is  critical  to  ensure  that  
the  amount  of  drag  on  both  the  operator  and  non-­‐operator  sides  is  the  same!  
 

d) Repeat  steps  3  &  4  by  adjust  the  proper  gapset  knobs  for:  

#2  fold  roll  to  main  fold  roll(strips  of  paper  in  between  the  #2  and  main  fold  rolls  
&  adjusting  the  #2  gapset  knobs),  then  

#3  fold  roll  to  #2  fold  roll(strips  of  paper  in  between  the  #3  and  #2  fold  rolls  &  
adjusting  the  #3  gapset  knobs),  then  
 
#4  fold  roll  to  #3  fold  roll(strips  of  paper  in  between  the  #4  and  #3  fold  rolls  &  
adjusting  the  #4  gapset  knobs),  then  
 
#5  fold  roll  to  #4  fold  roll(strips  of  paper  in  between  the  #5  and  #4  fold  rolls  &  
adjusting  the  #5  gapset  knobs.  
 

5. Now  that  all  of  the  fold  roll  pressures  have  been  calibrated  properly,  while  holding  each  gapset  

knob  so  that  it  does  not  move(if  the  gapset  knob  turns,  the  fold  roll  pressures  will  change),  turn  
each  gapset  indicator  dial  so  that  each  dial  is  set  at  1.  