Baumfolder BAUM1620 Gapset Calibration User Manual

Page 8

Advertising
background image

8  

 

Recalibrating  Fold  Roll  Pressures  for  Fold  Roll  Wear:    

Safety:  

1. It  is  recommended  to  shut  incoming  power  off  to  the  folder  by  using  the  main  power  

disconnect  located  on  the  parallel  unit  or  disconnecting  power  to  the  machine  by  unplugging  it  
from  any/all    power  source(s).  
 

2. Due  to  possible  injury,  never  attempt  or  allow  anyone  to  attempt  to  set  the  fold  roll  gapsets  

while  the  fold  rolls  are  running.  

 

 

 

Adjusting  fold  rolls  due  to  normal  wear  and  tear  on  the  folder  is  common.  Recalibrating  the  fold  

rolls  for  this  is  very  easy.  

1. Remove  plastic  caps  from  the  top  of  all  of  the  gapset  knobs.  

 

2. Loosen  the  nuts  in  all  of  the  gapset  knob  cavity  using  a  ½”  or  13mm  nut  driver.  

 

3. Place  (1)  1”  wide  strip  of  20#  bond  paper  towards  the  outer  portion  of  the  main  and  #1  fold  rolls  

ensuring  that  the  paper  is  making  full  contact  with  the  urethane  bands  of  the  fold  rolls.  

Plastic  Binder  Plug  

Set  Screw

Cap  

Gapset  Knob  

Gapset  Setting  Dial  Indicator  w/  Label  

Foldhead  Frame  

Fold  Roll  

Elastic  Stop  Nut  

Gapset  Rod/Block  
Weldment  

Advertising