Factory  Calibration  of  1620  Gapsets  &  Field/Service  Fold  Roll  Replacement:  

1. The  proper  fold  roll  gapset  calibration  sequence  is  as  follows:  

 

a) #1  fold  roll  to  main  fold  roll  
b) #2  fold  roll  to  main  fold  roll  
c) #3  fold  roll  to  #2  fold  roll  
d) #4  fold  roll  to  #3  fold  roll  
e) #5  fold  roll  to  #4  fold  roll  

This  sequence  of  setting  the  fold  rolls  must  be  followed,  as  not  doing  so  may  result  in  improper  
calibration  of  the  fold  rolls  causing  inaccurate/crooked  folds.  

2. Ensure  that  there  is  an  equal  gap  on  both  the  operator  and  non-­‐operator  sides  between  all  fold  

rolls.  This  gap  only  needs  to  be  large  enough  to  allow  a  single  sheet  thickness  of  20#  bond  paper  
to  freely  be  slid  between  the  rolls.  
 

-­‐ To  increase  the  gap  between  the  fold  rolls,  turn  the  gapset  knob  clockwise  
 
-­‐ To  decrease  the  gap  between  the  fold  rolls,  turn  the  gapset  knob  counter-­‐clockwise.  

 

3. Place  (1)  1”  wide  strip  of  20#  bond  paper  towards  the  outer  portion  of  the  main  and  #1  fold  rolls  

ensuring  that  the  paper  is  making  full  contact  with  the  urethane  bands  of  the  fold  rolls.  
 

 

As  you  place  each  strip  of  paper  into  the  proper  fold  rolls  that  you  are  calibrating  the  gapsets  
for,  it  is  helpful  to  turn  the  gapset  knob  counter-­‐clockwise  until  the  strip  of  paper  is  being  held  
lightly  by  the  fold  rolls.    

-­‐ While  placing  the  strip  of  paper  on  the  operator  side  of  the  fold  rolls,  adjust  the  #1  

gapset  knob  on  the  operator  side.  
 

-­‐ While  placing  the  strip  of  paper  on  the  non-­‐operator  side  of  the  fold  rolls,  adjust  the  #1  

gapset  knob  on  the  non-­‐operator  side.  