Baumfolder BAUM1620 Gapset Calibration User Manual

Page 12

Advertising
background image

12  

 

7. While  holding  the  gapset  knob  so  it  does  not  turn,  tighten  the  elastic  stop  nut  located  in  the  

cavity  of  the  gapset  knobs  slowly  to  ensure  that  it  just  contacts  the  gapset  knob.  This  is  done  
using  a  1/2”  or  13mm  nut  driver.  Do  this  for  all  gapset  knobs.  
 
 Do  not  torque  this  nut  onto  the  gapset  knob,  only  tighten  this  nut  until  it  just  touches  the  
gapset  knob!  
 

 

 
These  nuts  on  top  of  the  gapset  knobs  serve  2  purposes:  
 

a) With  the  nuts  just  tightened  until  they  are  just  touching  the  gapset  knobs  while  

the  gapset  is  set  in  between  1  &  15,  the  operator  can  now  adjust  the  fold  roll  
pressures  for  running  a  thinner  stock  than  20#  bond  such  as  Bible  paper,  etc.  
 

b) If  the  operator  is  able  to  set  the  gapsets  to  a  gapset  setting  greater  than  15,  the  

operator  can  just  turn  the  gapset  knob  counter-­‐clockwise  until  it  contacts  this  
nut.  The  operator  can  then  turn  the  knob  clockwise  until  a  gapset  setting  of  1.  
The  fold  roll  pressure  for  this  roll  should  now  be  set  for  a  single  sheet  of  20#  
bond  paper.  

 

8. Turn  all  of  the  gapset  knobs  back  to  1.  It  is  recommended  that  you  check  the  fold  roll  pressures  

of  all  fold  rolls  by  using  1”  wide  strips  of  20#  bond  paper  ad  doing  the  pull  test.  IF  the  fold  roll  
pressures  remained  the  same  with  all  gapset  knobs  set  at  1,  then  you  may  proceed  to  the  next  
step.  If  the  fold  roll  pressures  do  not  feel  correct,  it  will  be  necessary  to  repeat  steps  4  -­‐  6  to  
properly  set  the  fold  roll  pressures.    
 

9. The  gapset  knob  caps  can  now  be  pressed  into  the  top  of  the  gapset  knobs.  

 

10. The  gapset  calibration  is  now  complete.  

 

Advertising