General information, Pretest procedures – Bendix Commercial Vehicle Systems VORAD VS-400 INSTALLATION NOTES User Manual
Page 19
Advertising
General Information
17
Pretest Procedures
Step
Procedure
I
1. Vehicle Ignition: Key-ON, Engine-OFF.
2 . Measure for ignition voltage on pins 10 and 9 of the harness connector .
a .
If the voltage is within 0 .6 volts of the battery voltage measured in Step A .
i .
Proceed to Step J .
b .
If the voltage is less than 0 .6 volts of the battery voltage measured in Step A or open .
i.
Test Failed. Check component fuse. Troubleshoot power supply to the FLR for open/corroded
connections or shorts to ground and repeat Step .
Pin #
Description
10
9
Advertising