90 appendices, Exclusice communication, Parameter address map – Boss Audio Systems GS-10 User Manual

Page 90: One way communication, Midi machine control (mmc), Request data 1 rq1(11h), Data set 1 dt1(12h), Inquiry message

Advertising
background image

90

Appendices

●MIDI Machine Control (MMC)

F0H 7FH 7FH 06H com F7H

F0H =

System Exclusive

7FH =

ID Number (Universal Realtime Message)

7FH =

Device ID (Broadcast)

06H =

Sub ID#1(Machine Control Command)

com =

Sub ID#2(MMC Command)

F7H =

EOX (End of Exclusive/System common)

*

“com” (MMC Command) that I transmit with GS-10 is following.

01H

Stop

02H

Play

44H 06H 01H 00H 00H 00H 00H 00H

RESET

06H

REC

3. EXCLUSICE COMMUNICATION

On the GS-10, exclusive messages can be used as follows. - Transmit/receive GS-10 system/
patch data.
The model ID for GS-10 exclusive messages is 00H 63H, and you can set up the device ID at
00H–1FH.

■ONE WAY COMMUNICATION

●Request Data 1

RQ1(11H)

F0H 41H dev 00H 63H 11H aaH bbH ccH ddH ssH ttH uuH vvH sum F7H

F0H =

Exclusive Status

41H =

Manufacturer ID

(Roland)

dev =

Device ID

(Dev=00H-1FH)

00H =

Model ID

MSB (GS-10)

63H =

Model ID

LSB (GS-10)

11H =

Command ID

(RQ1)

aaH =

Address

MSB

bbH =

Address

:

ccH =

Address

:

ddH =

Address

LSB

ssH =

Size

MSB

ttH =

Size

:

uuH =

Size

:

vvH =

Size

LSB

sum =

Checksum

F7H =

EOX

(End of System Exclusive)

*

This message can only be received, and is not transmitted from the GS-10.

*

When transmitting large Size values spanning fragmented addresses, the data can be
transmitted only to those addresses that are contiguous.

●Data Set 1

DT1(12H)

F0H 41H dev 00H 63H 12H aaH bbH ccH ddH eeH ... ffH sum F7H

F0H =

Exclusive Status

41H =

Manufacturer ID

(Roland)

dev =

Device ID

(dev = 00H-1FH)

00H =

Model ID

MSB (GS-10)

63H =

Model ID

LSB (GS-10)

12H =

Command ID

(DT1)

aaH =

Address

MSB

bbH =

Address

:

ccH =

Address

:

ddH =

Address

LSB

eeH =

Data

: =

:

ffH =

Data

sum =

Checksum

F7H =

EOX

(End of System Exclusive)

*

When transmitting large amounts of data spanning fragmented addresses, the data can
be transmitted only to those addresses that are contiguous.

●Inquiry Message

❍Identity Request

F0H 7EH 10H 06H 01H F7H

F0H =

Exclusive Status

7EH =

ID Number

10H =

Device ID

06H =

Sub ID#1

01H =

Sub ID#2

F7H =

EOX (End of System Exclusive)

*

The 7FH (Broadcast) device ID is also supported.

*

When an Identity Request is received, the GS-10 will transmitted the following Identity
Reply.

❍Identity Reply

F0H 7EH 10H 06H 02H 41H 63H 01H 00H 00H 00H 00H 00H 00H F7H

F0H= Exclusive

Status

7EH=

ID Number (Universal Non-realtime Message)

10H= Device

ID

06H= Sub

ID#1

02H= Sub

ID#2

41H= ID

Number

(Roland)

63H 01H=

Device Family Code

00H 00H=

Device Family Number Code

00H 00H 00H 00H= Software Revision Level
F7H=

EOX (End of System Exclusive)

*

When an Identity Request is received, the GS-10 will transmitted the following Identity
Reply.

4. PARAMETER ADDRESS MAP

The address and size are displayed under 7-bit hexadecimal notation.

Address

MSB

LSB

Binary

0aaa aaaa

0bbb bbbb

0ccc cccc

0ddd dddd

7-bit Hexadecimal

AA

BB

CC

DD

Size

MSB

LSB

Binary

0sss ssss

0ttt tttt

0uuu uuuu

0vvv vvvv

7-bit Hexadecimal

SS

TT

UU

VV

Advertising