C

onstruCtion

M

aster

P

lus

eZ

12

1. Clear Calculator:

OOO

2. Start Materials function:

N

3. If necessary, continue pressing

N

until

BLoCKS displays

4. Start Blocks function:

e

5. Enter 18′ Wall Length:

18fe

6. Enter 6′ 6" Wall Height:

6f6ie

7. Accept 8" default value for Block Height:

e

8. Accept 16" default value for Block Length:

e

9 Accept 5% default value for Waste Factor and solve for Blocks:

e

nUMBer oF BLoCKS

139.

e

CoVeraGe area

117. SQ Feet

drywall

required entries

Possible Solutions

Room Length

Room Width

Room Height

Ceiling

1. Y (Yes, include)

2. N (Don′t include)

Sheet Length

Default value: 8′

Sheet Width

Default value: 4′

Number of Sheets - Total

Number of Sheets – Wall

Number of Sheets – Ceiling

Joint Tape Length

Ready-Mix Compound Weight

Number of Drywall Screws

Number of Drywall Nails

Total Wall Area

Total Ceiling Area

Total Drywall Area

optional entries

Waste Factor

Default value: 5%

Find the amount of Drywall materials needed for a room 30′ long, 25′ wide

and 9′ high. Include the Drywall for the ceiling and use default values for

sheet length, sheet width and waste factor:
1. Clear Calculator:

OOO

2. Go to Materials function:

N

3. If necessary, continue pressing

N

until

drYWaLL displays

4. Start Drywall function:

e

5. Enter 30′ Room Length:

30fe

6. Enter 25′ Room Width:

25fe

7. Enter 9′ Room Height:

9fe

8. Include Drywall for Ceiling:

1e

9. Accept 8′ default value for Sheet Length:

e

10. Accept 4′ default value for Sheet Width:

e

11. Accept 5% default value for Waste Factor and solve for Drywall Materials:

e

nUMBer oF SheetS ttL

58.

e

nUMBer oF SheetS WaLL

33.

e

nUMBer oF SheetS CeiL

25.

e

Joint taPe Lnth

731 Feet 0 inCh

e

readY-MiX CoMP. LBS.

256.

e

drYWaLL SCreW QtY.

2284.

e

drYWaLL naiL QtY.

3655.

e

totaL WaLL area

990. SQ Feet

e

totaL CeiLinG area

750. SQ Feet

e

totaL drYWaLL area

1740. SQ Feet

Fencing

required entries

Possible Solutions

Fence Length

Number of Horizontal Rails

Maximum Post Spacing

• Default value: 96"

Post Width

• Default value: 3-1/2"

Number of:

• Fence Sections

• Posts

• Rails

Uniform Rail Length

Maximum Rail Length Remainder

Using the default values, calculate Materials needed for a 75′, 3-rail Fence.
1. Clear Calculator:

OOO

2. Go to Materials function:

N

3. If necessary, continue pressing

N

until

FenCinG displays

4. Start Fencing function:

e

5. Enter Fence Length:

75fe

6. Enter Number of Rails:

3e

7. Accept 96" default value for Maximum Post Spacing:

e

8. Accept 3-1/2" default value for Post Width and solve for Fencing:

e

FenCe SeCtion QtY.

10.

e

FenCe PoSt QtY.

11.

e

FenCe raiL QtY.

30.

e

UniForM raiL Lnth

7 Feet 2-1/8 inCh

e

MaX raiL LenGth reM

0 Feet 2-1/2 inCh

Footings

required entries

Possible Solutions

Footing Length

Footing Area

Default value: 264 sq inches

Waste Factor

Default value: 5%

Footing Volume

optional entries

Waste Factor

Default value: 5%

Calculate Footing Volume needed for a Footing 60′ long using a 256 sq. inch

(16"x16") Footing Area.
1. Clear Calculator:

OOO

2. Go to Materials function:

N

3. If necessary, continue pressing

N

until

FootinG displays

4. Enter 60′ Footing Length:

60fe

Advertising