C

onstruCtion

M

aster

P

lus

eZ

6

e

CoMMon CheeK anGL

38.66°

e

irreGULar CheeK anGL

51.34°

advanced hip/Valley rafters

required entries

Possible Solutions

Two of the first three required:

• Common Pitch

• Run (or Span)

• Rise

Total Hip/Valley Length

Hip/Valley Tail Length*

Plumb Angle

Level Angle

Common and Irregular

• Cheek Angle

• Backing Angle

• Sheathing Angle

• Plan Angle

optional entries

Irregular Pitch

Horizontal Overhang

Total Fascia Thickness

Ridge Thickness

• Default value: 1-1/2"

* Tail Length shown only when Horizontal Overhang is entered.

advanced Function with Common Pitch

Find Hip/Valley Lengths and Angles using an 8" Common Pitch, a 12′ Run, an

18" Horizontal Overhang and 2-1/4" Total Fascia Thickness:
1. Clear Calculator:

OOO

2. Start Advanced Hip/Valley function:

Ch

3. Enter 8" Common Pitch:

8ie

4. Enter 12′ Run:

12fe

5. No Irregular Pitch (Common Pitch used):

e

6. Enter 18" Overhang*:

18ie

7. Enter 2-1/4" Total Fascia Thickness*:

2i1 / 4e

8. Accept 1-1/2" default value for Ridge Thickness* and solve for Hip/Valley:

e

totaL hiP/VaLLeY Lnth

20 Feet 9-7/8 inCh

e

h/V raFter taiL Lnth

25-7/8 inCh

e

PLUMB anGLe

25.24°

e

LeVeL anGLe

64.76°

e

CoMMon CheeK anGLe

45.00°

e

CoMMon BaCKinG anGL

23.09°

e

CoMMon SheathinG anGL

50.24°

e

CoMMon PLan anGL

45.00°

* If the desired value is already displayed, there′s no need to re-enter it. Just press

e

to accept it. The value you store will remain unchanged until you modify it or reset the

calculator.

Optional Entries only: If you don′t want to include an optional entry in your calculation,

simply clear it by entering

0e

.

advanced Function with irregular Pitch

Find Hip/Valley Lengths and Angles using an 8 " Common Pitch, a 12′ Run, a

10" Irregular Pitch, an 18" Overhang and 2-1/4" Total Fascia Thickness:
1. Clear Calculator:

OOO

2. Start Advanced Hip/Valley function:

Ch

3. Enter 8" Common Pitch:

8ie

4. Enter 12′ Run:

12fe

5. Enter 10" Irregular Pitch:

10ie

6. Enter 18" Overhang*:

18ie

7. Enter 2-1/4" Total Fascia Thickness*:

2i1 / 4e

8. Accept 1-1/2" Ridge Thickness* and solve for Hip/Valley:

e

totaL hiP/VaLLeY Lnth

19 Feet 2– 9/16 inCh

e

h/V raFter taiL Lnth

23-3/4 inCh

e

PLUMB anGLe

27.50°

e

LeVeL anGLe

62.50°

e

CoMMon CheeK anGL

38.66°

e

irreGULar CheeK anGL

51.34°

e

CoMMon BaCKinG anGL

20.27°

e

irreG BaCKinG anGL

29.99°

e

CoMMon SheathinG anGL

56.35°

e

irreG SheathinG anGL

46.16°

e

CoMMon PLan anGL

51.34°

e

irreGULar PLan anGL

38.66°

* If the desired value is already displayed, there′s no need to re-enter it. Just press

e

to accept it. The value you store will remain unchanged until you modify it or

reset the calculator.

Optional Entries only: If you don′t want to include an optional entry in your calculation,

simply clear it by entering

0e

.

JaCK rafTer funCTion

Basic Jack rafters

required entries

Possible Solutions

Two of the first three required:

• Common Pitch

• Run (or Span)

• Rise

On-Center Spacing

• Default value: 16"

Common and Irregular

• Jack On-center Spacing*

• Offset Length

• Rafter Length

• Jack Rafter Lengths

• Plumb Angle

• Level Angle

• Cheek Angle

optional entries

Irregular Pitch

*On-Center Spacing is also a possible solution that displays when both of the following

are true: 1) Common and Irregular Pitches are not equal and 2) Jack Alignment

Preference is set to

MATE, rather than ON-CENTER.

Find the Jack Rafter Lengths and Angles using an 8" Common Pitch and a

6′ Run:
1. Clear Calculator:

OOO

2. Start Jack Rafter function:

j

3. Enter 8" Common Pitch:

8ie

4. Enter 6′ Run:

6fe

5. No entry for Irregular Pitch (Common Pitch used):

e

6. Accept default On-Center Spacing (16") and solve for Jack Rafters:

e

CoMMon oFFSet Lnth

19-1/4 inCh

e

CoMMon raFter Lnth

7 Feet 2-9/16 inCh