ClearCube C/Port & MVX User Manual

Page 12

Advertising
background image

2

ClearCube C/Port Overview

C/Ports are connected via standard twisted-pair copper networking cables: CAT5, CAT5e,

CAT6, or CAT6e.

Table 1

lists the distance limits for C/Port installations.

Note: When configuring an Admin Daisy Chain connecting 9 or more R4300 chassis, the

Admin C/Port must be located within 100 meters of the equipment rack if using CAT5

or CAT5e cable, or within 50 meters of the equipment rack if using CAT6e. When the

Admin Daisy Chain has 8 R4300 chassis or fewer, or is composed entirely of R4200

chassis, the standard distance lengths for C/Port cabling apply.

Figure 1. ClearCube C/Port

Table 1. C/Port Connection Limits

Cable Type

Distance

CAT5

660 feet (200 meters)

CAT5e

660 feet (200 meters)

CAT6

*

C7130: 330 feet (100 meters)

CAT6, CAT6e

*

*

C7120 or earlier: 330 feet (100 meters)

C7130: 660 feet (200 meters)

*

Cable certified for 45 nS / 100 meters delay skew or less.

* *

Cable certified for 25 nS / 100 meters delay skew or less.

Note: C/Port connections use all four twisted pairs in a straight-through connection.

Advertising