Troubleshooting

• 37

Appendix A. Troubleshooting

If you have any problems with your system, please check the following items prior to calling

for support.

C/Ports

Red link status indicator on PC blade and C/Port

Check cables for correct pin-out, which is the same as for standard Ethernet over CAT5

cable. Check that all wire pairs are terminated properly.

Pin 1 and 2 are pairs

Pin 3 and 6 are pairs

Pin 4 and 5 are pairs

Pin 7 and 8 are pairs

Check the back edge of the PC blade for any debris that may be causing incomplete

contact between the blade and the connectors in the chassis.

Check for debris on all RJ-45 jacks.

Certify the cable with a cable analyzer.

For a dual processor PC blade, verify the C/Port cable is plugged into the even numbered

port (e.g., for a PC blade installed in chassis slots 3 and 4, the C/Port cable should be

plugged into port 4).

No link status indicator light

Troubleshooting procedure is the same as above.

Poor video quality

Re-adjust the C/Port.

Check for cabling problems.

Replace monitor and re-adjust C/Port.

Use monitor auto adjust utility for flat panel LCD monitors.

Set refresh frequency to 60 Hz for LCD monitor or try varying the refresh rate to find the

best picture quality.

For LCD monitors, use the monitor’s native resolution, or the manufacturer’s

recommended resolution.

Advertising