Troubleshooting

• 37

Appendix A. Troubleshooting

If you have any problems with your system, please check the following items prior to calling

for support.

C/Ports

Red link status indicator on PC blade and C/Port

•

Check cables for correct pin-out, which is the same as for standard Ethernet over CAT5

cable. Check that all wire pairs are terminated properly.
–

Pin 1 and 2 are pairs

–

Pin 3 and 6 are pairs

–

Pin 4 and 5 are pairs

–

Pin 7 and 8 are pairs

•

Check the back edge of the PC blade for any debris that may be causing incomplete

contact between the blade and the connectors in the chassis.

•

Check for debris on all RJ-45 jacks.

•

Certify the cable with a cable analyzer.

•

For a dual processor PC blade, verify the C/Port cable is plugged into the even numbered

port (e.g., for a PC blade installed in chassis slots 3 and 4, the C/Port cable should be

plugged into port 4).

No link status indicator light

•

Troubleshooting procedure is the same as above.

Poor video quality

•

Re-adjust the C/Port.

•

Check for cabling problems.

•

Replace monitor and re-adjust C/Port.

•

Use monitor auto adjust utility for flat panel LCD monitors.

•

Set refresh frequency to 60 Hz for LCD monitor or try varying the refresh rate to find the

best picture quality.

•

For LCD monitors, use the monitor’s native resolution, or the manufacturer’s

recommended resolution.