Warning, Aintenance and care, Replace light bulb – Bissell 18Z6 User Manual

Page 13: Turbobrush maintenance

Advertising
background image

WARnInG:

To reduce the risk of electric

shock, turn Power Switch Off

and disconnect polarized plug

from electrical outlet before

performing maintenance or

troubleshooting checks.

M

aintenance and care

Replace light bulb

1. Unplug cleaner from electrical outlet.
2. Remove detachable canister and recline

handle of vacuum.

3. Using a screwdriver, remove the one screw

as shown and lift off the lens.

4. Remove the bulb from the socket by grasping

bulb and pulling straight out. Install the new

bulb by pushing it gently into the socket until

the bulb snaps into place.

5. Reposition lens and secure with the one

screw.

TurboBrush maintenance

The TurboBrush should be checked regularly

for clogs or debris wrapping around the

brush roll.

1. Unplug vacuum from electrical outlet.

2. If a clog is present or debris is visible,

unscrew the two screws on the back of the

TurboBrush to remove the faceplate and clear

any obstructions.

3. To clean debris from the brush roll, remove

the screw located on the belt cover. Lift the

belt cover. Remove the brush roll from the

drive belt and clean debris.

4. Reposition the drive belt on the brush roll.

Place ends of brush roll in slots on sides

as shown. Reposition belt cover and secure

with shorter screw. Reposition faceplate and

secure with two longer screws.