Application Bulletin 403/1 e

Installation instruction for MVA-21:
894 Professional CVS fully automated for CVS determinations

The «MVA-21» is a fully automated system for the

determination of suppressor and brightener in plating

solutions.

PC controlled operation.

Manual operations:

o

Filling of the sample vials on the Sample

Processor with suppressor standard solution,

plating bath samples and rinsing solution.

Automatic addition of 4 solutions: VMS, brightener

concentrate, suppressor concentrate and suppressor

standard or plating bath sample.

Automatic rinsing of the measuring vessel.

Method change during the determination series is

possible.

Applications:

o

Analysis of suppressor concentration in plating

baths with CVS.

o

Analysis of brightener concentration in plating

baths with CVS.

Fig 1 MVA-21

Content

1.

Instruments and accessories .......................................... 2

2.

System setup .................................................................. 2

2.1.

Electrical connections ......................................... 2

2.2.

Tubing connections for rinsing and draining of the
measuring vessel ................................................ 3

2.3.

Tubing connections for automatic dosing of
standard solutions and auxiliary solutions ........... 4

3.

viva Configuration ........................................................... 5

3.1.

Devices – 894 Profesional CVS .......................... 5

3.2.

Sensors/Electrodes ............................................. 5

3.3.

Dosing units ........................................................ 5

3.4.

Solutions ............................................................. 6

3.5.

Devices – 858 Professional Sample Processor for
CVS ..................................................................... 6

3.6.

Needle adjustment .............................................. 7

4.

viva «Method» ................................................................ 8

4.1.

Method run .......................................................... 8

4.2.

Evaluation ........................................................... 9

5.

Operation...................................................................... 10

5.1.

Suppressor determination series ...................... 10

5.2.

Brightener determination series ........................ 11

6.

Remarks ....................................................................... 12

6.1.

Single additive setup ......................................... 12

6.2.

Combination of applications .............................. 12

6.3.

Storing dosing units........................................... 12

6.4.

Storing electrodes ............................................. 12

6.5.

Waste container ................................................ 12

Page 1 of 12