Application Bulletin 402/1 e

Installation instruction for MVA-20:
894 Professional CVS fully automated for CVS determinations

The «MVA-20» is a fully automated system for the

determination of suppressor and brightener in plating

solutions in small sample series.

PC controlled operation.

Manual operations:

o

Filling of the sample vials on the Autosampler

with suppressor standard solution, plating bath

samples and rinsing solution.

Automatic addition of 4 solutions: VMS, brightener

concentrate, suppressor concentrate and suppressor

standard or plating bath sample.

Automatic rinsing of the measuring vessel.

Method change during the determination series is

possible.

Applications:

o

Analysis of suppressor concentration in plating

baths with CVS.

o

Analysis of brightener concentration in plating

baths with CVS.

Fig. 1: MVA-20

Content

1.

Instruments and accessories .......................................... 2

2.

System setup .................................................................. 2

2.1.

Electrical connections ............................................ 2

2.2.

Tubing connections for rinsing and draining of the
measuring vessel ................................................... 3

2.3.

Tubing connections for automatic dosing of
standard solutions and auxiliary solutions .............. 4

3.

viva «Configuration» ....................................................... 5

3.1.

Devices – 894 Profesional CVS ............................. 5

3.2.

Sensors/Electrodes ................................................ 5

3.3.

Dosing units ........................................................... 5

3.4.

Solutions ................................................................ 6

3.5.

Devices – 919 IC Autosampler plus for CVS ......... 6

4.

viva «Method» ................................................................ 8

4.1.

Method run ............................................................. 8

4.2.

Evaluation .............................................................. 9

5.

Operation...................................................................... 10

5.1.

Suppressor determination series ......................... 10

5.2.

Brightener determination series ........................... 11

6.

Remarks ....................................................................... 12

6.1.

Single additive setup ............................................ 12

6.2.

Combination of applications ................................. 12

6.3.

Storing dosing units ............................................. 12

6.4.

Storing electrodes ................................................ 12

6.5.

Waste container ................................................... 12