Creating the presenceplus inspection, Inspection. see, Creating the – Banner PresencePLUS P4 COLOR Series User Manual

Page 65: Presenceplus inspection

Advertising
background image

Main Tasks to Complete

Step 3

2. Click the OK button to accept the configuration.

Kawasaki Protocol Defaults

The default Kawasaki protocol configuration parameters are:

• Ethernet Socket 1 configured for TCP/IP Port 20000 as the communications channel
• No Frame Start (Command Start) delimiter
• Carriage Return/Line Feed as Frame End (Command End) delimiter
• Space as the input command field separator
• Comma as the output field separator.

Note: You can adjust each of these parameters as necessary, but corresponding
adjustments will have to be made to the sample AS Language program provided to
enable successful communication.

Creating the PresencePLUS Inspection

Main Tasks to Complete

Step 1

Enable the Coordinate
Tool
in the Tool
Configuration dialog.

1. Click the System button in the upper-right corner of the PresencePLUS GUI.

2. Select the Tools Configuration tab.

65