Watts PWR4011 User Manual

Pure water, Series pwr4011, Commercial reverse osmosis systems

Advertising
background image

For Commercial Applications

ES-WQ-PWR4011

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Series PWR4011

Series PWR4011

Commercial Reverse Osmosis

Systems

Flow Rates: Up to 5,400 gpd (20,439 lpd)

Watts Pure Water Series PWR4011 reverse osmosis (RO) sys-

tems are commercial grade low-energy RO units for the reduc-

tion of total dissolved solids from water. They are designed

to supply reverse osmosis quality water with production rates

ranging from 1,800 to 5,400 gallons per day. These units are

designed for wall mount installations. Reverse osmosis is a

process where high-pressure feed water is fed into a semi-

permeable membrane. In the membrane, pure water is allowed

to pass through the membrane material and exit as purified

permeate water. Dissolved mineral salts are not allowed to

pass through the membrane and become a concentrated

reject stream that is sent to a drain. These RO systems use

low-energy membranes to achieve a minimum average NaCl

ionic rejection of 95 percent.
Watts Pure Water Series PWR4011 RO systems are a well

designed, rugged line of purifiers with high-pressure piping

constructed of stainless steel. This series comes with a pre-

selected assortment of features for monitoring and operation.

Stainless steel membrane housings and high-pressure piping,

inlet and outlet pre-filter pressure gauges, low-pressure switch

with delayed auto restart, inputs for tank level and pretreatment

interlock, adjustable reject recycle, permeate and reject water

flow meters, permeate water check valve, inlet solenoid valve,

membrane feed water pressure gauge, and adjustable reject

valve are all standard features. These systems are designed to

feed an atmospheric storage tank for collection of the reverse

osmosis water. Reverse osmosis water has a wide variety of

applications including municipal water treatment, steam boiler

and steam sterilizer make up, laboratory use, spot free rinsing,

ice and beverage water, water for cooking, food processing,

metal plating and finishing, as well as water for humidification.

Reverse osmosis is also the pretreatment of choice for ion

exchange type de-ionization (DI) systems. Using RO water as

make up to a DI system reduces the exhaustion rate of the DI

resin by up to 95 percent saving time, money, and chemicals

associated with DI resin regeneration.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Features

• Stainless steel high-pressure piping
• 304 stainless steel wall mounted support frame
• 316L stainless steel 300psi high-pressure membrane

housings

• Pressure gauges for pre-filter inlet/outlet and membrane

feed pressure

• Low feed water pressure safety switch
• Microprocessor based controller with delayed auto restart

after low-pressure shut down

• Tank level and pretreatment interlock inputs
• Low-energy membranes with 95% minimum average salt

rejection

• Permeate and reject water flow meters
• Adjustable reject and reject recycle valves
• Permeate check valve
• Automatic inlet solenoid valve
• 10" high flow pre-filter

Standards

• Pre-filter Housing NSF/ANSI Certified 42

PURE WATER

Note:

Do not use with water that is microbiologically unsafe or

of unknown quality without adequate disinfection before or after

the system.