Watts LF210-5 User Manual

Series lf210-5, Lead free, Automatic gas shutoff valves

Advertising
background image

Series LF210-5

Automatic Gas Shutoff Valves

Series LF210-5 automatic gas shutoff valves are positive-acting energy

shutoff for the emergency temperature protection of gas water heaters.

They are self-contained devices independent of all other operating con-

trols. They provide protection against overheating water in the domestic

hot water supply heating systems by automatically shutting off the gas

supply to the heater in the event that the water temperature reaches

210°F (99°C). Series LF210-5 must be manually reset in order to resume

heater service. This feature serves as a warning of malfunctioning of

the normal operating controls. Manual resetting is easily done and does

not require dismantling or replacing of any part of the valve. See “Reset

Button” feature. The LF210-5 features Lead Free* construction to comply

with Lead Free* installation requirements.
This gas shutoff differs from other contemporary design in that Watts

engineers have embodied the time tested Watts auto-thermatic thermal

actuator principle along with a snap-acting trip latch which closes the

valve at a definite controlled temperature.
Models LFL210-5 M2, LFLL210-5 M2 and LFLLL210-5 M2 feature

extended shanks for use with the new generation of water heaters con-

taining extra thick insulation.

Features

•  Seating - Buna N disc to metal seating assures positive seal for

shutting off the gas to burner in the event of high water tempera-

ture conditions.

• Reset Button - After operating from high temperature, the gas

shutoff must be manually reset (opened). Pressing the reset button

in as far as it will go and then releasing, opens the valve and allows

gas to again flow to the burner.

• Trip Latch Assembly - Snap acting latch releases the valve to

closed at a definite controlled temperature. Stainless steel spring

seats valve when trip latch releases valve to closed position

• Thermostat - Operates trip latch in response to water temperature.

Thermobulb, temperature sensitive portion, is at end of extension

tube for accurate response to tank temperature.

Models

LF210-5 M2

Suitable for water heaters with up to

3

4

" of insulation

LFL210-5 M2 Suitable for water heaters with up to 2" of insulation
LFLL210-5 M2 Suitable for water heaters with up to 2

1

2

" of insulation

LFLLL210-5 M2 Suitable for water heaters with up to 3" of insulation

Specifications

Standard setting: 210°F (99°C)
Extension: Furnished with 5" thermostat extension only.

LF210-5 M2

LFL210-5 M2

LFLL210-5 M2

LFLLL210-5 M2

Thermostat

Reset Button

For Gas Water Heater Applications

ES-LF210-5

LEAD FREE

*

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

NOTICE

Inquire with Governing Authorities for Local Installation Requirements