Watts LF07S User Manual

Series lf07s, Lead free, For residential fire sprinkler applications

Advertising
background image

Series LF07S

Residential Fire Sprinkler

Dual Check Backflow Preventer

Sizes: 1" – 2" (25 – 50mm)

The Watts Model LF07S Residential Fire Sprinkler Dual Check

Backflow Preventer is designed for non-health hazard [i.e., pollutant]

application on potable fire sprinkler service connections to protect

against possible backsiphonage conditions that could inadvertently

drain the fire sprinkler system.

Approvals - Standards

Please consult Local Governing Code for proper installation and

agency code requirements,

ANSI/NFPA 13, 14, 15, 20, 22, and 24 Compliant -

All Sizes Applicable
End Connections – National Pipe Thread Taper ANSI B1.20.1

Pressure - Temperature

Max. Working Pressure: 175psi (12.1 bar) 1

1

2

" & 2"

160psi (11.03 bar) 1" & 1

1

4

"

Min. Working Pressure:

10psi (0.69 bar)

Hydrostatic Test Press:

700psi (48.3 bar)

Temperature Range:

33°F to 140°F (0.5°C to 60°C)

1" & 1

1

4

"

33°F to 180°F (0.5°C to 82°C)

1

1

2

" & 2"

For Residential Fire Sprinkler Applications

ES-LF07S

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

2" LF07SU2-2

1" LF07SU2-2

LEAD FREE

*

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

1024

Sizes Applicable: 1", 1

1

2

" & 2" Only

All Sizes Applicable

Sizes Applicable: 1" Only

B64.6

Specifications

The Lead Free* Dual Check Valve Backflow Preventer shall be

ASSE

®

Listed 1024 and be UL Classified. The main body shall

be Lead Free* brass featuring replaceable seats and silicone seat

discs. The check assemblies shall have captured springs to pre-

vent injury. The Dual Check Valve shall be a Watts Model LF07S.

Material Specifications

• Body: Lead Free* Brass
• Elastomers: Silicone
• O-Rings: EPDM or Buna N
• Check Modules: Engineered Plastics
• Springs: Stainless Steel

Typical Installation

The Model LF07S is typically installed for service on residential fire

sprinkler systems. It is recommended this device is installed after

a water meter and/or isolation shutoff valve with installation tech-

niques that comply with the latest edition of the Uniform Plumbing

Code. Please consult Local Governing Code for proper installation

and agency code requirement.