Membrane replacement – Watts PWROKCZRO User Manual

Page 8

Advertising
background image

8

Membrane Replacement

This reverse osmosis system contains a replaceable component (the

RO membrane) which is critical to the efficiency of the system.
Replacement of this reverse osmosis membrane should be with one

of identical specifications as defined by Watts to assure the same

efficiency and contaminant reduction performance.
Membranes have a life expectancy between 2 and 5 years, de-

pending on the incoming water conditions and the amount the

RO system is used . This reverse osmosis membrane is critical for

effective reduction of total dissolved solids (TDS) . The product water

should be tested periodically to verify that the system is performing

satisfactorily .
Normally, a membrane would be replaced during a semiannual or

annual filter change . However, if at any time you notice a reduction

in water production or an unpleasant taste in the reverse osmosis

water, it could be time to replace the membrane . Watts recommends

replacing the membrane when TDS reduction falls below 75% .
Note: A water sample may be sent to Watts for a free diagno-

sis of your membrane performance. To send a water sample,

use two (2) clean containers and fill ½ cup of tap water in one

container and ½ cup of reverse osmosis water in 2nd container.

Clearly label each sample. Send the samples to the address

listed on the cover of this manual attention “Water Samples”.

Watts will test the water and mail or call you with the results.
See annual maintenance on Page 7.
Step A – To change your membrane follow the instructions for the

Annual Maintenance (previous section) . The procedure to

remove and change the membrane cartridge is the same

as all the other filter cartridges on the RO module .

Step B – Check over the next 24 hours to ensure no leaks

are present .

Replacement Filter Packs

Model

Frequency

description

PWKCCB13

6 months

Carbon Block

PWFPKKCZW

Annual

Membrane and filters

PWKCGAC13

Annual

GAC filter

PWMEMKC60

2-5 years

60 GPD membrane

Advertising