Watts R14-06-1111000 User Manual

R-14 floor-mounted systems, Models, Specifications

Advertising
background image

Models

Model Number

PACK-

AGE

GPD

Pump

(H.P.)

Recovery

(Adj.)

Membrane

Size

Membranes

Feed Water

Required*

(GPM)

Typical

Rejection

Dimensions

Ship

Wt.

(Lbs.)

R14-02-1111000

1

3600

5

25%-75%

4" x 40"

2

5

98%

60"x18"x56"

400

R14-02-1131100

2

3600

5

25%-75%

4" x 40"

2

5

98%

60"x18"x56"

400

R14-03-1111000

1

5400

5

36%-75%

4" x 40"

3

7.50

98%

60"x18"x56"

500

R14-03-1131100

2

5400

5

36%-75%

4" x 40"

3

7.5

98%

60"x18"x56"

500

R14-04-1111000

1

7200

5

42%-75%

4" x 40"

4

10

98%

60"x18"x56"

600

R14-04-1131100

2

7200

5

42%-75%

4" x 40"

4

10

98%

60"x18"x56"

600

R14-05-1111000

1

9000

5

46%-75%

4" x 40"

5

12.5

98%

60"x18"x56"

700

R14-05-1131100

2

9000

5

46%-75%

4" x 40"

5

12.5

98%

60"x18"x56"

700

R14-06-1111000

1

10800

5

50%-75%

4" x 40"

6

15

98%

60"x18"x56"

800

R14-06-1131100

2

10800

5

50%-75%

4" x 40"

6

15

98%

60"x18"x56"

800

Specifications

Feed water connection

1" FNPT

Product water connection

3/4" FNPT

Reject water connection

3/4" FNPT

Feed water pressure requirement (min.)

10 PSIG

Drain requirement (maximum)

15 GPM

Electrical requirement

230VAC/60hz

Phase

3

Amps

15

*At 50% recovery.

®

WATER QUALITY & CONDITIONING PRODUCTS

R-14 floor-mounted systems

Five models for flow rates to 10,800 GPD. Select
the features you want to meet your requirements!

Standard features (package #1)

Powder coated steel frame

Stainless steel pressure vessels

Pre-filter housing and cartridge (20" Full-Flow)

Webtrol

®

heavy-duty multi-stage centrifugal pump

Automatic inlet valve

Low-pressure shut-off with automatic restart

Tank level input

Pretreatment interlock input

Adjustable recycle line

Pre-filter pressure gauges

Pump discharge pressure gauge (liquid filled)

Flow meter for product water

Flow meter for reject water

Flow meter for recycle water

Check valve for product water

On / off switch

Additional features included with package #2

CI-1000 electronic controller with product
water conductivity meter and alarm output

Programmable concentrate auto flush

R14-06-1131100 System

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature
conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.
Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro

®

FPMB-BB5-20 melt blown cartridge.

Systems are designed for use with municipal and well water.

Advertising
This manual is related to the following products: