Watts FPSF-2 Tee Fitting User Manual

Serie fpsf, Série fpsf, Series fpsf

Advertising
background image

ENGLISH

INSTRUCTIONS

IS-FPSF

1116

EDP# 2915858

© Watts,

2011

US

A:

815

C

hes

tnu

t S

t.,

No.

A

ndo

ver

, M

A 0

184

5-6

098

; w

ww

.w

att

s.c

om

Can

ad

a:

543

5 N

ort

h S

erv

ice

R

d.,

Bur

lin

gto

n,

ON

. L

7L

5H

7;

ww

w.w

att

sca

nad

a.c

a

Residential Fire Sprinkler Fitting

Mounting:

Predetermine suitable mounting location per fire sprinkler installation plan.
Mounting stud or joist must be square to the future finished surface for proper

alignmentof the sprinkler head.
Position the pendent fitting to the required depth on stud or joist and screw the

mounting feet securely into place. Use the proper screw for the material. Screw

should be at least 1-

1

2

" #10 course thread. For proper depth measurements,

please refer to the dimensional diagrams in the Watts NFPA 13D-Residential

Fire RF PEX

TM

Multipurpose Piping Installation guide.

L = Hmin, Hmax should be obtained from the sprinkler manufacturer information.
T = Drywall Thickness
D = Estimated Sprinkler Fitting Hole Location

Dmin = L – T– Hmax – .375.

Dmax = L – T– Hmin – .375.

T

D

L

Hmin

Hmax

2. Pipe is cut square

and stops at fitting

shoulder

4. CrimpRing is evenly

compressed over the pipe,

and shows no evidence of

uneven distortion.

1. Fitting

shoulder

location

3. CrimpRing is positioned

1/8" - 1/4" from end of the

pipe, directly over two end

ribs of fitting.

RF PEX

TM

Connection:

Cut RF PEX

TM

tubing to desired length. Make sure that tubing is cut squarely,

and all burrs are removed. Slide correctly sized crimp ring over end of tub-

ing. Remove protective caps from barbed connections on the pendent fitting

and slide tubing over the connection until the tubing touches the shoulder of

the fitting. Slide crimp ring over the tubing fitting connection until it is

1

/

8

" to

¼" from the end of tubing. The crimp ring should be positioned directly over

the two ribs closest to the end of the fitting.

Position crimp tool at a 90° angle to the pipe so that the jaws completely

cover the crimp ring. Compress the jaws completely. Check connection with

Go/No-Go gauge. If the connection does not gauge correctly, cut out the

joint, recalibrate the tool, and start again.

BEFORE INSTALLING WATTS RESIDENTIAL RF FIRE PEX

TM

COMPONENTS, YOU MUST THOROUGHLY READ THE WATTS

NFPA 13D - RESIDENTIAL FIRE RF PEX

TM

MULTIPURPOSE PIPING

INSTALLATION GUIDE AVAILABLE AT WWW.WATTS.COM FOR

FURTHER INFORMATION INCLUDING ADDITIONAL PRODUCT-

SAFETY INFORMATION AND THE PRODUCT WARRANTY.

This information is not intended to provide full installation guidelines

or the experience of a trained product installer. To the extent the Guide

is not consistent with local building or plumbing codes, the local codes

should be followed.

FAILURE TO COMPLY WITH PROPER INSTALLATION

INSTRUCTIONS COULD RESULT IN DAMAGE TO THE

MULTIPUPOSE PIPING SYSTEM, INCLUDING, THE FIRE

SUPPRESSION SYSTEM WHICH CAN RESULT IN PROPERTY

DAMAGE, PERSONAL INJURY AND/OR DEATH.
The Guide and these instructions do not address design and installa-

tion requirements for any system, nor do they address hydraulic calcu-

lations, sprinkler selection, installation and/or performance. YOU ARE

REQUIRED TO CONSULT WITH A CERTIFIED FIRE PROTECTION

DESIGN PROFESSIONAL, LICENSED RESIDENTIAL FIRE

SUPPRESSION SYSTEM INSTALLER AND THE AUTHORITY HAVING

JURISDICTION WHEN INSTALLING A MULTIPURPOSE SYSTEM.
• Watts does not provide design or installation services or instructions

and shall not be held responsible for system design or installation

errors.

• This product is intended to work with residential multipurpose fire

suppression sprinklers with NFPA 13D systems rating at a maximum

of 130psi (896 kPa) at 120°F (48.9°C) when used in a multipurpose

system. The type of sprinkler for any system shall be limited to that

specified and approved by the authority having jurisdiction for the

given installation. DO NOT use this product for systems required

to meet NFPA 13, 13R or 13D stand-alone systems.

• WATTS IS NOT RESPONSIBLE FOR INADEQUATE WATER

PRESSURE OR WATER SUPPLY. Refer to a certified fire protection

design professional to ensure the proper water pressure and supply

is available for the application.

WARNING

!

• In a multipurpose system, where the residential fire PEX tubing (RF PEX

TM

tubing) serves both fire sprinklers and domestic use, devices that restrict the

water flow or decrease the pressure or automatically shut off the water to the

fire suppression system, such as water softeners, filtration systems, and auto-

matic shutoff valves, shall not be added without a review of the fire suppres-

sion system by a fire protection specialist. Additionally, appropriate signage

is required for the end user. Refer to NFPA 13D for further information.

• DO NOT use any damaged products. Before assembling any components,

inspect all products for manufacturing defects, cuts, scrapes, gauges, splits

or any other irregularities that occur during shipping and handling.

• In order to ensure proper operation of the multipurpose system, the product

must be used with Watts UL 1821 listed RF PEX

TM

tubing, residential fire PEX

fittings (RF fittings), residential fire PEX sprinkler fittings (RF PEX

TM

Series FPSF

sprinkler fittings) and CrimpRing™ connections and require protection by any

of the following: 1) 3/8" thick or thicker gypsum wallboard 2) A suspended

membrane ceiling with lay-in panels or tiles having a weight of not less than

0.35 lb/ft2 when installed with metallic support grids 3) ½" plywood

or plywood soffits.

• DO NOT use air or compressed gas for pressure testing. The use of air or

compressed gas can cause system failure and/or product damage, property

damage, personal injury and/or death.

• These products are designed for use in environments with ambient tempera-

ture ranges between 40°F and 120°F. DO NOT allow the multipurpose system

to freeze. Freezing temperatures can damage component parts causing water

damage and/or damage to the fire suppression system which can result in

property damage, personal injury and/or death.

• In order to prevent damage to the Watts components, avoid over torqueing

when installing the sprinkler into the multipurpose system. Refer to the

sprinkler manufacturer’s instructions for proper installation requirements.

• Periodic Maintenance is required pursuant to the Guide, NFPA 13D and local

and national codes.

IS-FPSF

1116

EDP# 2915858

© Watts,

2011

US

A:

815

C

hes

tnu

t S

t.,

No.

A

ndo

ver

, M

A 0

184

5-6

098

; w

ww

.w

att

s.c

om

Can

ad

a:

543

5 N

ort

h S

erv

ice

R

d.,

Bur

lin

gto

n,

ON

. L

7L

5H

7;

ww

w.w

att

sca

nad

a.c

a

IS-FPSF

1116

EDP# 2915858

© Watts,

2011

US

A:

815

C

hes

tnu

t S

t.,

No.

A

ndo

ver

, M

A 0

184

5-6

098

; w

ww

.w

att

s.c

om

Can

ad

a:

543

5 N

ort

h S

erv

ice

R

d.,

Bur

lin

gto

n,

ON

. L

7L

5H

7;

ww

w.w

att

sca

nad

a.c

a

IS-FPSF

Serie FPSF

Empalme de

aspersor para

incendios residenciales

Tam

año

s: 2

0 –

25

m

m (¾

p

ulg

. –

1

pul

g.)

Autorizado por

UL 1821

Série FPSF

Raccord de

gicleur résidentiel

Tai

lle

s :

20

mm

et

25

m

m (0

,75

p

o e

t 1

p

o)

Homologué UL

1821

Series FPSF

RF

PEX

TM

R

esi

den

tia

l

Fire

S

prin

kle

r F

itti

ng

Siz

es:

3

4

" –

1"

(2

0 –

25

mm

)

UL

182

1 li

ste

d

FPSF-2 Tee

Fitting

FPSF-2 Empalme

en T

Raccord en

T FPSF-2

FPSF-1S

Straight Fitting

FPSF-1S

Empalme recto

Raccord droit

FPSF-IS

FPSF-1L Left

Fitting

FPSF-1L

Empalme a

la izquierda

Raccord côté

gauche FPSF-1

L

FPSF-1R Right

Fitting

FPSF-1R Empalme

a la

derecha

Raccord côté

droit FPSF-1R

3

4

" -

1

" (2

0-2

5m

m)

Ins

tal

lat

ion

In

str

uct

ion

s

Ins

tru

cci

one

s d

e in

sta

lac

ión

Ins

tru

ctio

ns

d’in

sta

lla

tio

n

Advertising
This manual is related to the following products: