VI. APPENDIX
The following tables are intended as a guide to determining the flow rates for the R14
series RO systems. All flows are in gallons per minute (GPM).
Nominal flows for systems without reject recycle
and a feed water Silt Density Index less than 3.
R14-02 R14-03 R14-04 R14-05 R14-06
Product 2.5
3.75
5 6.25
7.5
Reject
6.1
5.9
5
4.7
4.6
Nominal flows for systems with reject recycle
and a feed water Silt Density Index less than 3.
R14-02 R14-03 R14-04 R14-05 R14-06
Product 2.5
3.75
5 6.25
7.5
Reject
2.5
3.75 1.7 2.1 2.5
Reject
Recycle
3.6 2.2 3.3 2.6 2.1
Nominal flows for systems without reject recycle
and a feed water Silt Density Index of 3 to less than 5.
R14-02 R14-03 R14-04 R14-05 R14-06
Product 2.3 3.5 4.3 5.2 6.3
Reject
6.6 6.5 5.3 4.8 4.4
Nominal flows for systems with reject recycle
and a feed water Silt Density Index of 3 to less than 5.
R14-02 R14-03 R14-04 R14-05 R14-06
Product 2.3 3.5 4.3 5.2 6.3
Reject
2.3 3.5 1.4 1.7 2.1
Reject
Recycle
4.3 3 3.9 3.1 2.3