Watts LF1XL User Manual

Lead free, Temperature and pressure relief valves

Advertising
background image

For Water Heater and Hot Water Storage Tank Applications

Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor

––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––– Approval

––––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative

–––––––––––––––––––––––––––––––––––––––––

LF10L

Series LF1L, LF1XL,

LF10L and LF100XL

Temperature and Pressure

Relief Valves

A.S.M.E Rated**, CSA Listed. Self-closing T&P Relief Valves

for Water Heaters up to 105,000 BTU/Hr.
The combined 2 in 1 T&P relief valve provides the least expen-

sive and proven means for protection against both excessive

temperature and pressure emergency conditions.
Provides fully automatic temperature and pressure relief protec-

tion for hot water storage tanks and heaters up to 105,000 BTU/

HR. Series LF10L furnished with test lever and short thermostat

for installation directly in tank tapping. Series LF100XL

furnished with test lever and extension thermostat for installa-

tion in the hot water outlet line or directly in the tank tapping.

Temperature sensing element must be immersed in the water

within the top 6" (152mm) of the tank. Male inlet and female out-

let. Temperature relief 210°F (99°C). Standard settings 75, 100,

125, 150psi (5.3, 7.0, 8.8, 10.6 bar). The LF1L, LF1XL, LF10L,

and LF100XL feature Lead Free* construction to comply with

Lead Free* installation requirements.

Features

• Series LF1L, LF1XL Size

1

2

" (15mm) LF10L, LF100XL Size

3

4

"

(20mm)

• A.S.M.E. Rated**, CSA Listed
• Features a unique thermostat with special thermo-bonded

coating

• An all Lead Free* copper silicon alloy body
• Stainless steel spring
• Thermostat is accurate and proven. Exclusively designed

and manufactured by Watts

Options

• For tanks and heaters with extra thick insulation, send for

literature ES-LFSL100XL/LFL100XL/LFLL100XL/LFLLL100XL

• Series 100XL-8 with 8" (200mm) extension thermostat
• Series LF1L, LF1XL Size

1

2

" (15mm): For both temperature

and pressure relief protection. Series LF1L has short thermo-

stat and test lever. Series LF1XL has extension thermostat with

thermo-bonded coating. Also available with 8" (200mm) exten-

sion thermostat

Specifications

T&P valves

Each water heater and hot water storage tank shall be equipped

with a CSA and A.S.M.E. Rated** automatic temperature and

pressure relief valve to protect the heater from excessive pres-

sure and temperature. Lead Free* Temperature and Pressure

Relief Valves (valve type, reduced pressure zone, etc.) shall

be constructed using Lead Free* materials. Lead Free valves

shall comply with state codes and standards, where applicable,

requiring reduced lead content. The device shall be ANSI Z21.22

certified. The BTU discharge capacity of the device shall be in

excess of the BTU input rating of the heater. Watts Series No.

LF1L, LF1XL, LF10L or LF100XL.

LF100XL

**Series LF1L and LF1XL Valves are not A.S.M.E. Listed or Rated.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

LEAD FREE

*

ES-LF1L_LF1XL_LF10L_LF100XL

NOTICE

Inquire with governing authorities for local installation

requirements

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

Following installation, the valve lever MUST be operated

AT LEAST ONCE A YEAR to ensure that the water-ways

are clear. Certain naturally occurring mineral deposits may

adhere to the valve, rendering it inoperative. When manually

operating the lever, water will discharge and precautions must be

taken to avoid contact with hot water and to avoid water dam-

age. BEFORE

operating lever, check to see that a discharge

line is connected to this valve directing the flow of hot water from

the valve to a proper place of disposal otherwise personal injury

may result. If no water flows, valve is inoperative.

TURN OFF

THE WATER HEATER AND CALL A PLUMBER IMMEDI-

ATELY.

This device is designed for emergency safety relief and shall not

be used as an operating control.

WARNING

!