Watts A2C-WB User Manual

Watts intelliflow, Operating instructions, Operating specifications

Advertising
background image

Watts IntelliFlow

®

Automatic Washing Machine Shutoff Valve
Model A2C-M1, A2C-WB-M1

Important! Read instructions completely before proceeding.

Note: This unit is not compatible with 240VAC powered wash-
ing machines or combination washer/dryers that are 240VAC
powered. A Watts A2-IntelliTimer (purchased separately) may be
used with the IntelliFlow

®

with washing machines or washer/dry-

ers that are 240VAC powered. (See page 5)

A2C-M1 IntelliFlow

®

Patent Number 6,003,536

Leak Sensor

IS-A2C-M1/A2C-WB-M1

*This valve requires a 120VAC, 60 Hz,
20 amp ground fault protected circuit.

*Ground Fault Interrupter – A GFI circuit is not required for
proper operation of the IntelliFlow

®

, but is strongly recom-

mended as a safety device.

Surge Protection – Although a surge protector is not
required for proper operation of the IntelliFlow

®

, it is strongly

recommended, especially in areas where power surges or
lightning strikes frequently occur.

Operating Instructions

The Watts IntelliFlow

®

Automatic Washing Machine Shutoff Valve is equipped with a

state-of-the-art electric current sensing device. When the washing machine is turned
on, the device senses current flow to the washing machine. This causes it to actuate
its solenoid water valves, allowing water to flow to the washing machine. When the
washing machine shuts off upon completion of the full wash cycle, the device senses
the lack of current and closes the water valves. The IntelliFlow

®

remains closed until

the next time you turn the washer on.

The leak sensor provides additional protection from water damage while the washing
machine is in operation. Water detected at the sensor results in immediate shut off of
water flow to the washing machine hose.

By installing an IntelliFlow

®

, you are protecting your home from potential major water dam-

age from a burst or leaking washing machine inlet hose.

Operating Specifications

Electrical Rating: 120VAC, 60 Hz

Circuit Breaker Requirements: 20A GFI*

Max. Appliance Current Rating: 15A

Current Draw: 20mA (with appliance off)

Electrical Cord: 6 ft. type SJT 14 AWG

Max. Temperature: 180°F (82°C)

Max. Pressure: 150psi (10.3 bar)

Valve Body: Reinforced Polysulfone

Rubber Goods: Buna-N, EPDM

*Ground Fault Interrupter – A GFI circuit is not required for proper operation of the
IntelliFlow

®

, but is strongly recommended as a safety device. In accordance with National

Electric Code, NFPA 70, Section 210.11 Branch Circuits Required, at least one 20-ampere
branch circuit shall be provided to supply the laundry receptacle outlets(s) required by
Section 210.52(F). This circuit shall have no other outlets.

*Surge Protection – Although a surge protector is not required for proper operation of the
IntelliFlow

®

, it is strongly recommended, especially in areas where power surges or lightning

strikes frequently occur.

Model
A2C-M1

from
washing
machine

Electrical

power source

ground fault

protected

Water supply

One for cold

One for hot

Model
A2C-WB

from
washing
machine

Electrical

power source

ground fault

protected

Water supply

One for cold

One for hot

Model A2C-M1

1

2

" solder connectors for exposed piping

Standardly furnished with

1

2

" solder copper

adapters. Either connection may be used for the
hot or cold water supply.

Model A2C-WB-M1

Includes wall mount box. Wall mount box has water
inlet connection holes spaced 2

3

8

" center to center.

Furnished with

1

2

" solder connectors. Either connec-

tion may be used for the hot or cold water supply.