Standard screens, Performance data, Flow-coefficient – Watts 87SI User Manual

Page 2: Dimensions — weights

Advertising
background image

Standard Screens

SIze

OpenIngS

Standard ScreenS

in.

mm

in.

mm

1

2

- 2

15-50

0.032

0.813

1

32

" 304SS perf.

2

1

2

- 3

65-80

0.045

1.143

3

64

" 304SS perf.

Performance Data

Table shows flow rates (gpm-water) at various pressure

drops (psi) for standard screens.

Flow-coefficient

The flow coefficient (Cv) is the number of gallons per minute

of water flowing through a given size restriction at a pressure

drop of one psi. To obtain the Cv factor for a given size

strainer, read capacity at intersection with the one (1) psi

pressure drop.
Conversions:

For gpm to lpm, multiply by 3.8. For psi

to bars, multiply by .069

in. mm

3

80

2

1

2

65

2

50

1

1

2

40

1

1

4

32

1

25

3

4

20

1

2

15

Strainer

Size

gpm lpm
500 1900

100 380

10

38

1

3.8

.5

1.9

0.1

1

10

Flow

(water)

-

gpm

pressure drop - psig

a

c

npt

B

Inlet

cap

npt/SW

Dimensions — Weights

SIze

dImenSIOnS

WeIghtS

A

B

C (NPT)

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

1

2

15

2

5

16

59

1

9

16

40

3

8

10

0.5

.2

3

4

20

3

1

8

79

2

1

8

54

3

8

10

0.8

.3

1

25

3

5

16

84

2

5

8

67

1

2

15

1.5

.6

1

1

4

32

4

1

8

105

3

76

1

2

15

2.0

.9

1

1

2

40

4

11

16

119

3

3

16

81

1

2

15

2.8

1.2

2

50

5

7

16

138

3

13

16

97

1

2

15

4.3

2.9

2

1

2

65

7

7

8

200

5

5

16

135

1

1

4

32

13.0

5.8

3

80

8

7

8

225

5

15

16

151

1

1

4

32

18.0

8.1

Dimensions shown are subject to change. Contact Watts for exact dimensions when required.

ES-87SI 0933

© 2009 Watts

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

A Watts Water Technologies Company

Advertising