Watts 519 173R User Manual

Adjustable tubular p-traps, For commercial & residential applications, Features

Advertising
background image

Adjustable Tubular P-Traps

Features

• Furnished with die cast nuts and shallow flanges

• Chrome finish

For Commercial & Residential Applications

ES-WB&T-501/50

2

/503/504/518/519

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

502, 504, 518, 519

with cleanout

MODEL

DESCRIPTION

 TO SUBMIT CLEANOUT

DIMENSIONS

FINISH

A

B

C

D

E

F

G

Y/N

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

501173

1

1

/

4

x 1

1

/

4

No

10

3

/

8

263.5

5

127

1

1

/

4

31.8

17 Ga.

3

76.2

7

3

/

8

187.3

2

1

/

2

63.5

Chrome

501173B

1

1

/

4

x 1

1

/

4

w/ brass nut

No

10

1

/

4

260.4

5

127

1

1

/

4

31.8

17 Ga.

3

76.2

7

1

/

4

184.2

2

3

/

8

60.3

Chrome

502173

1

1

/

4

x 1

1

/

4

Yes

10

3

/

8

263.5

5

127

1

1

/

4

31.8

17 Ga.

3

76.2

7

3

/

8

187.3

2

1

/

2

63.5

Chrome

503173

1

1

/

2

x 1

1

/

2

No

11

1

/

4

285.8

5

3

/

8

136.5

1

1

/

2

38.1

17 Ga.

3

3

/

8

85.7

7

7

/

8

200

3

76.2

Chrome

503173B

1

1

/

2

x 1

1

/

2

w/ brass nut

No

11

279.4

5

1

/

4

133.4

1

1

/

2

38.1

17 Ga.

3

1

/

4

82.6

7

5

/

8

193.7

2

3

/

8

60.3

Chrome

503173BG

1

1

/

2

x 1

1

/

2

w/ground joint

No

11

279.4

5

1

/

2

139.7

1

1

/

2

38.1

17 Ga.

3

1

/

4

82.6

7

7

/

8

200

3

1

/

2

88.9

Chrome

504173

1

1

/

2

x 1

1

/

2

Yes

11

1

/

4

285.8

5

3

/

8

136.5

1

1

/

2

38.1

17 Ga.

3

3

/

8

85.7

7

7

/

8

200

3

76.2

Chrome

518173

1

1

/

4

x 1

1

/

4

w/cast body

Yes

10

1

/

8

257.2

4

5

/

8

117.5

1

1

/

4

31.8

17 Ga.

2

1

/

2

63.5

7

1

/

2

190.5

2

50.8

Chrome

519173

1

1

/

2

x 1

1

/

2

w/cast body

Yes

10

3

/

4

273.1

5

127

1

1

/

2

38.1

17 Ga.

2

7

/

8

73

7

7

/

8

200

2

1

/

2

63.5

Chrome

519173R

1

1

/

2

x 1

1

/

4

w/cast body

Yes

10

3

/

4

273.1

5

127

1

1

/

4

31.8

17 Ga.

2

7

/

8

73

7

7

/

8

200

2

1

/

2

63.5

Chrome

Series 501, 502, 503, 504, 518, 519

A

E

D

C

F

G

Cleanout

Less Cleanout

501, 503

less cleanout

A

E

D

C

F

B

G

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

B r a s s & T u b u l a r P r o d u c t s

ES-WB&T-501/502/503/518/519

0639

© Watts Regulator Company, 2006

B

Advertising