910 link

• Throttles to reduce high upstream pressure to

constant lower downstream pressure

1

X

X

X

Y/FC

P/L

3

2

CLOSES VALVE

OPENS VALVE

FLOW

(AOS)

M115 (Globe)

M1115 (Angle)

PRESSURE REDUCING

CONTROL VALVE

The Watts ACV Pressure Reducing Control Valve is designed to automatically reduce a fluctuating higher

upstream pressure to a constant lower downstream pressure regardless of varying flow rates. It is con-

trolled by a normally open, pressure reducing pilot designed to: 1) Open (allowing fluid out of the main valve

cover chamber) when downstream pressure is below the adjustable setpoint, and 2) Close (allowing fluid to

fill the main valve cover chamber) when downstream pressure is above the adjustable setpoint. A decrease

in downstream pressure causes the valve to modulate toward an open position, raising downstream pres-

sure. An increase in downstream pressure causes the valve to modulate toward a closed position, lowering

downstream pressure.

Operations

1 – Main Valve (Single Chamber)

2 – Pressure Reducing Control

3 – Fixed Orifice

• Reducing setpoint is adjustable