Watts R4X40-3 User Manual

Page 13

Advertising
background image

RO SYSTEM TROUBLE SHOOTING

PROBLEM REMEDY

General

High Product Water TDS

Membrane frozen, high temp, or backpressure. Replace

membrane.

Membrane attack by chlorine

Carbon pre-filter may be exhausted. Replace filter and membrane.

Product seal on end cap.

Determine if seal or o-ring is bad. Replace as needed.

No Product Water or Not Enough Product Water

Feed water shut off.

Turn on feed water.

Low feed pressure. Feed pressure must be at least 10 psi.

Consider booster pump.

Pre-filter cartridge clogged.

Replace pre-filter cartridge.

Membrane fouled.

Determine and correct cause; replace or clean membrane.

Product check valve stuck.

Clean or replace check valve.

Low pump discharge pressure
Low feed water temperature

Adjust reject valve or replace pump
Increase membrane feed pressure or heat the feed water.



IV.

REPLACEMENT PARTS LIST

A list of common replacement parts is provided below. Contact your dealer for replacement
parts assistance.

Part Number

Description

FPMB5-20

Prefilter, 5 micron, melt blown

R9622-WLE

RO membrane, low energy

R2451

Prefilter pressure gauge 0 – 100 psi

PG20B25

Pump discharge pressure gauge 0 – 300 psi

R4507

Product flow meter 0.5 – 5 gpm

R5316

Reject flow meter with valve 0.5 – 5 gpm

WDM-2 Water

quality

meter

R6316-HPS7D

Pump & motor 0.75 HP for R4X40-1

R6316-HPS7E

Pump & motor 1.0 HP for R4X40-2

R6316-HPS10F

Pump & motor 1.5 HP for R4X40-3

R23-1070S Controller

with on/off switch (R4X40-1)

R23-1072S

Controller with on/off switch (R4X40-2 & R4x40-3)

R2316-PS32

Low pressure switch, ¼” MPT

T1100

Recycle needle valve PVC

R2482-120

Inlet solenoid valve, ¾”, 120 volt coil

R96-PV-4040-OS Pressure

vessel with end caps, 316 SS