Sizing

CAVITATION ZONE

INLET PRESSURE - PSI

OUTLET PRESSURE - PSI

300

280

260

240

220

200

180

160

140

120

100

80

60

40

20

0

10 20

40

50

60

70

80

90

130 140

120

110

100

30

CAVITATION CHART

After selecting the valve size, locate inlet and outlet pressures on this chart. If the intersection point falls

in the shaded area, cavitation can occur. Operation of valves continually in the cavitation zone should be

avoided. Consult Watts ACV for alternatives.

Cavitation Chart

Size (in)

1-1/4

1-1/2

2

2-1/2

3

4

6

8

10

Maximum Continuous (GPM)

95

130

210

300

485

800

1850

3100

5000

Maximum Intermittent (GPM)

119

161

265

390

590

1000

2300

4000

6250

Minimum Continuous (GPM)

1

1

1

20

30

50

115

200

300

Maximum continuous fl ow based on velocity of 20 ft. per second.

Maximum intermittent fl ow based on velocity of 25 ft. per second.

Minimum continuous fl ow based on velocity of 1 ft. per second.

NOTE: The above chart is a suggested guide. Inlet pressure, outlet pressure, minumum, normal and maximum fl ow rates should

be considered for specifi c valve sizing. Contact Watts ACV for details.