Watts FPTS16-OS User Manual

Lead free, Rf pex, Residential fire tubing

Advertising
background image

Sizes:

3

4

" – 1" (20 – 25mm)

RF PEX

TM

Tubing is used for residential fire PEX multipurpose

piping systems used to support NFPA 13D, which is the stan-

dard covering the “Installation of Sprinkler Systems in One

and Two-Family Dwellings and Manufactured Homes.”

RF PEX

TM

tubing's unique orange tracer stripe facilitates fire

official's inspection.

UL Listed Pressures and Temperatures

80psi (552 kPa) at 200°F (93.3°C)

(If RF Tubing is used for Hot Water Lines,

Not intended for Fire Suppression use)
100psi (689 kPa) at 180°F (82.2°C)

(If RF Tubing is used for Hot Water Lines,

Not intended for Fire Suppression use)
130psi (896 kPa) at 120°F (48.9°C)

(Residential Fire Rating)
160psi (1103 kPa) at 73.4°F (23°C)

(For Reference Only)

Specifications

RF PEX

TM

Tubing is only to be used with RF PEX

TM

Fittings,

RF PEX

TM

Sprinkler Fittings

and Copper CrimpRings

TM

all of which

are UL 1821 listed. These products are designed for use with

residential 13D multipurpose fire suppression piping and pota-

ble water plumbing applications. RF PEX

TM

tubing also has an

orange tracer stripe to aid in identification.

Approvals

The below listings are solely based upon use of Watts UL 1821

listed RF PEX

TM

Tubing, RF PEX

TM

Fittings and CrimpRing

TM

connections.

Manufactured in accordance with the American Society for

Testing and Materials (ASTM) F-876 and F-877 to SDR-9

dimensional standards.
Tested and certified by NSF International to NSF/ANSI

Standards 14 and 61 for use in potable water systems.
Labeled B137.5 which indicates that it is compliant to the

CSA standards B137.5.
When not connected to the fire suppression system,

Certified PEX5306 is acceptible for use in continuous hot

water recirculation.
Can withstand up to 6 months of continuous UV exposure.
ASTM E-84 and CAN/ULC 102.2 smoke developed and flame

spread classification.
Fire Resistance per CAN/ULC S101 and ASTM E119-08
AWWA C904.
UL 1821 listed for use in Residential Fire Sprinkler

Systems per NFPA 13D.

For Residential Fire Sprinkler Applications

ES-RF-PEX

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

LEAD FREE

*

*The wetted surface of this product contacted by consumable

water contains less than one quarter of one percent (0.25%)

of lead by weight.

RF PEX

RF PEX

TM

Residential Fire Tubing