Watts LFCS User Manual

Model lfcs, Lead free, Check stop valves

Advertising
background image

Model LFCS

Check Stop Valves

Sizes:

1

2

"

Model LFCS check stop valves are designed for use at the hot and

cold water inlet sup plies for mixing and tem per ing valves. Model

LFCS valves perform triple duty as: 1) iso la tion valves,

2) check valves, and 3) strain ers. The union con nec tions

facilitate service and main te nance of both the valve and the

strainer.
Model LFCS valve protects against cross flow of hot and cold

water in the system and provide isolation of the mixing or

tem per ing valve during ser vic ing and main te nance of the valve

and strain er. The integral fine strainer protects the valve from

dam ag ing dirt and other debris.The Model LFCS valve features

Lead Free* construction to comply with Lead Free* installation

requirements.

Features

• Performs triple duty as: 1) check valve, 2) shutoff

valve, and 3) strainer

• Check valve function protects against hot and cold

water supply cross flow

• Shut-off function facilitates mixing valve ser vice and

strainer maintenance

• Strainer protects mixing valves from dirt and other

debris

• Universal design eliminates left-hand/right-hand

confusion

Materials

Body:

Lead Free* Copper Silicon Alloy

O-rings:

EPDM

Strainer:

Stainless steel

Spring:

Stainless steel

Disc:

EPDM

Stem:

Lead Free* Brass

Specifications

LFCS combination check/stop/strain er valve shall be used at the

hot and cold wa ter inlets to the Watts LFL111 and LFMMV mix ing

valves. The combination check stop valve(s) shall be a Watts model

LFCS, as in di cat ed on the installation plans. The combination check

stop valve shall be of lead free con struc tion. Lead Free* check stop

shall comply with state codes and standards, where applicable,

requiring reduced lead content. The check stop valve shall be fit ted

with a strainer to pre vent large par tic u late mat ter from entering the

valve. The check stop valve shall be fitted with a union con nec tion

to fa cil i tate the re mov al of the mixing valve and the ser vic ing of the

strain er. The check stop valve inlet connection shall be threaded

(-T). The outlet connection shall be threaded (-UT). The check/stop/

strainer valve(s) used shall be the Watts LFCS Check Stop valve.

Pressure – Temperature

Maximum Working Pressure: 150psi (10.3 bar) at 225°F (107°C)

LFCS-T-UT

For Mixing Tempering Valve Applications

ES-LFCS

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

LEAD FREE

*

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.