Refill Flow Control Assembly or Refill Port Plug
To clean or replace the refill flow control, pull out the elbow-locking clip and then pull straight up on the elbow. Replace the elbow
locking clip in the slot so that it is not misplaced. Twist to remove the white flow control retainer. The flow control can be removed
by prying upward through the side slots of the retainer with a small flat blade screwdriver.
Chemically clean the flow control or the white flow control retainer using dilute sodium bisulfite or vinegar. Do not use a wire brush.
If necessary, replace the flow control, o-ring on the flow control retainer, or the o-ring on the elbow.
Reseat the flow control so the rounded end is visible in the flow control. Reseat the white flow control retainer by pushing the
retainer into the elbow until the o-ring seats. Remove locking clip, push down on elbow to reseat and insert locking clip.
Do not use Vaseline, oils, or other unacceptable lubricants on o-rings. A silicone lubricant may be used on the o-ring on the elbow or
the white retainer.
Meter Plug
This control valve does not come equipped with a meter, instead a plug is installed. The plug should not need to be serviced.
To remove the meter plug assembly, unscrew the meter cap on the left side of the control valve. Pliers may be used to unscrew the
nut if necessary.
With the nut removed, a slot at the top of the meter plug is visible. Twist a flat blade screwdriver in the slot between the control
valve body and the meter plug. When the meter plug is part way out it is easy to remove the meter plug from the housing.
Do not use a wire brush to clean the meter plug. Wipe with a clean cloth or chemically clean in dilute sodium bisulfite or vinegar.
Do not use Vaseline, oils, or other unacceptable lubricants on the o-ring. A silicone lubricant may be used on the black o-ring.
Reinsert the meter plug into the side slot. Hand tighten the nut. Do not use a pipe wrench to tighten nut.
Compliance Table
Application
Injector and/or Plug(s)
Main Piston
Regenerant
Piston
Stack
Body
WS1TC Downflow
Softener or Regenerating
Filter
Injector in “DN” hole, Plug
in “UP” hole
V3011
V3174
V3005
V3001 or
V3001-02 (Mixing)
WS1TC Backwash Only
Filter
Plug in “DN” and “UP”
holes, Install Refill Port Plug
V3011
None
V3005
V3001 or
V3001-02 (Mixing)
WS1.25TC Downflow
Softener or Regenerating
Filter (1.32" Distributor)
Injector in “DN” hole, Plug
in “UP” hole
V3407
V3174
V3430
V3020 or
V3020-01 (Mixing)
WS1.25TC Backwash
Only Filter (1.32"
Distributor)
Plug in “DN” and “UP”
holes, Install Refill Port Plug
V3407
None
V3430
V3020 or
V3020-01 (Mixing)
WS1.25TC Downflow
Softener or Regenerating
Filter (32mm Distributor)
Injector in “DN” hole, Plug
in “UP” hole
V3407
V3174
V3430
V3020-02 or
V3020-03 (Mixing)
WS1.25TC Backwash
Only Filter (32mm
Distributor)
Plug in “DN” and “UP”
holes, Install Refill Port Plug
V3407
None
V3430
V3020-02 or
V3020-03 (Mixing)
Two holes are labeled DN and UP. Check for compliance. See Table.
Push the plug(s) and/or injectors firmly in place, replace the screen and hand tighten the injector cap.