Provide 120 Volt AC primary power. 
Do not dim the fixture through a dimming circuit. 
If powering the fixtures through a dimmer board, set the dimmer profile to 
non-dim. 
 
Load Considerations: 
 
Kino Flo ballasts are not power factor corrected. They will draw double the 
current on the neutral from what is being drawn on the two hot legs. On large 
installations it may be necessary to double your neutral run so as not to 
exceed your cable capacity. 
 
 
 
 
 
 
 
IMAGE 80, 40 and 20 DMX Fixtures may be operated manually with the 
Manual Lamp Selector Dial. The Dial enables you to turn lamps on and off 
with an “inside-out” pattern (i.e., if all lamps are on, the outside tubes will turn 
off first). 
 DMX Image 80 Switching 
 
 
 
 
 
 
 
 
 
 
 
 DMX Image 40 Switching 
 