6. Application of Checktool

(1) Running

Enter the destination folder of Fitouch and find the folder named as “checkTool”. Open the
folder and double click “checktool.exe” to display the dialog:

Run Checktool, there are “ DeviceInfo”, “Init”, “CheckAll”, “CheckOne”, “CheckAllResult” in
the interface.
If the device is not connected, the entire select buttons can not be selected and VersionInfo
shows Unknow. If the device is connected, Please start testing.

(2) All Infrared Tubes Testing

Click “CheckAll” to test all infrared tubes' data. If there is no abnormal situation, All Light Info
displays all infrared tubes' data. If so, CheckAllResault at the right side will show a column of
“exceptional light”. This column displays the position and data of abnormal infrared tubes.
Then click “CheckError”, select “BoardNum” and “LightNum” in “CheckOne”.

(3) Single Infrared Tube Testing

This function is used to detect one pair tubes' signal strength of sending and receiving and
analyze their working state. Click “Cur” and the IR control data will be displayed in
“CheckOneResault”; click “Next”, “Pre”, then all broken infrared values will be detected one
by one.

(4) Full Screen Testing

Press F2 to draw line on the screen and perform full screen test. this function can detect and
reveal the maximum area touching information so as to detect the problem of broken line in
certain area.
Note: Due to the size of display area is inconsistent with that of touch area, display point may
not coincide with touch point.
Press F2 to quit the full screen inspection when inspecting.

(5) Initialization

This function is used for factory setting test, when the initialization value of certain position is
0, it means the infrared transmiting and receiving of the mentioned position is abnormal, so
reparing is needed for this position.

Application of Checktool