Cutmaster 10mm, 12mm, 03 air supply connections – Tweco CutMaster 10mm-12mm User Manual

Page 22

Advertising
background image

CUTMASTER 10MM, 12MM

INSTALLATION 3-2 Manual 0-5197AC

3.03 Air Supply Connections

A. Connecting Air Supply to Unit

The connection is the same for compressed air or indus-
trial compressed air in gas cylinders.

1. Connect the gas line to the compressed air inlet

port at the appropriate pressure.

Art # A-10223

Air Inlet, 1/4” NPT

On/Off
Switch

Figure 3-1 - Gas Connection to Compressed Air Input

1/4 NPT
Hose Fitting

Hose
Clamp

Gas Supply Hose

Filter Hose

Single-Stage

Filter Kit

No. 7-7507

ART# A-10675

Figure 3-2 - Optional Single - Stage Filter Installation for

Compressed Air Input

B. Using Industrial Compressed Air In Gas Cylinders

When using industrial compressed air in gas cylinders
as the gas supply:

1. Refer to the manufacturer’s specifi cations for

installation and maintenance procedures for high
pressure gas regulators.

2. Examine the cylinder valves to be sure they are

clean and free of oil, grease or any foreign mate-
rial. Briefl y open each cylinder valve to blow out
any dust which may be present.

3. The cylinder must be equipped with an adjust-

able high-pressure regulator capable of outlet
pressures up to 100 psi (6.9 bar) maximum and
fl ows of at least 250 scfh [Standard cubic foot
per hour] (120 lpm) [liter per minute].

4. Connect gas supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at
the high pressure gas cylinder regulator.

Supply hose must be at least 1/4 inch (6mm)
internal diameter.

For a secure seal, apply thread sealant to the
fi tting threads, according to manufacturer's
instructions. DO NOT use Tefl on tape as a
thread sealer, as small particles of the tape
may break off and block the small gas pas-
sages in the torch.

Advertising