Cutmaster 10mm, 12mm – Tweco CutMaster 10mm-12mm User Manual

Page 25

Advertising
background image

CUTMASTER 10MM, 12MM

Manual 0-5197AC 4-3 OPERATION

B. Torch

Connection

Check that the torch is properly connected.

C. Check Primary Input Power Source

1. Check the power source for proper input voltage. Make sure the input power source meets the power require-

ments for the unit per Section "2.05

Power Source Specifi cations" on page 2-2.

2. Connect the input power cable (or CLOSE the main disconnect switch) to supply power to the system.

D. Gas Selection

Ensure gas source meets requirements listed in Section "H.

Gas Requirements" on page 2T-1. Check connec-

tions and turn gas supply ON.

E. Connect Work Cable

Clamp the work cable to the workpiece or cutting table. The area must be free from oil, paint and rust. Connect
only to the main part of the workpiece; do not connect to the part to be cut off.

Art # A-03387

Figure 4-4 - Work Cable Connection

F. Power

ON

Place the Power Source ON/OFF switch to the ON (I) position. Power indicator

turns ON.

Art# A-10225

Air Inlet, 1/4” NPT

On/Off
Switch

Power Cord

Figure 4-5 - Rear Panel with ON/OFF Switch

A

30

20

40

Art# A-10219

Power indicator

Figure 4-6 - Front Panel with Power ON/OFF Indicator

Advertising