Cutmaster 10mm, 12mm – Tweco CutMaster 10mm-12mm User Manual

Page 27

Advertising
background image

CUTMASTER 10MM, 12MM

Manual 0-5197AC 4-5 OPERATION

NOTE

When the shield cup is properly installed, there
is a slight gap between the shield cup and the
torch handle. Gas vents through this gap as
part of normal operation. DO NOT attempt to
force the shield cup to close this gap. Forcing
the shield cup against the torch head or torch
handle can damage components.

• Drag Cutting With a Hand Torch

Drag cutting works best on metal 1/4" (6mm) thick
or less.

NOTE

For best parts performance and life, always
use the correct parts for the type of operation.

A. Install the drag cutting tip and set the output

current.

B. The torch can be comfortably held in one hand

or steadied with two hands. Position the hand
to press the Trigger on the torch handle. With
the hand torch, the hand may be positioned
close to the torch head for maximum control
or near the back end for maximum heat protec-
tion. Choose the holding technique that feels
most comfortable and allows good control and
movement.

C. Keep the torch in contact with the workpiece

during the cutting cycle.

D. Hold the torch away from your body.
E. Slide the trigger release toward the back of the

torch handle while simultaneously squeezing
the trigger. The arc will start.

Art # A-09342

Trigger

Trigger Release

Figure 4-10 - Torch Trigger Release

F. Place the torch tip on the work. The main arc

will transfer to the work.

NOTE

The gas prefl ow and postfl ow are a character-
istic of the Power Source and not a function
of the torch.

3

4

Trigger

2

1

Trigger Release

Art# A-09341

Figure 4-11 - Drag Cutting

G. Cut as usual. Simply release the trigger as-

sembly to stop cutting.

H. Follow normal recommended cutting practices

as provided herein.

3. Complete cutting operation.

NOTE

If the torch is lifted too far from the workpiece
while cutting, the main arc will stop and the
pilot arc will automatically restart.

4. Release the torch trigger.

a. Main arc stops.

5. Set the Power Source ON/OFF switch to OFF (down

position).

a. AC indicator

turns OFF.

6. Set the main power disconnect to OFF, or unplug

input power cord.
a. Input power is removed from the system.