Manual 0-2805

3-7

INSTALLATION

Power Supply Adapter

Pilot Lead

Torch Lead

Assembly

Negative/Plasma

Lead

Negative/Plasma
Lead Connection

A-03610

Control Circuit

Connectors

Remote
Pendant
Adapter

Open

Open

Adapter

Connector

Pilot Lead

Stud

Torch Lead Connections To Bulkhead

A-03611

Pilot Lead

Torch Lead

Assembly

Negative/Plasma

Lead

Control Circuit

Connectors

Open

Open

Power Supply Adapter

Torch Lead Connections To Bulkhead - Detail

5. Connect the Control (PIP) Circuit Connectors to

the mating connectors on the Adapter supplied
on the Power Supply (see Warning).

WARNING

The Adapter supplied with the Power Supply has
two additional Shield Connectors that are used for
Shielded Systems only. These two connectors are
not used and must be taped out of the way to pre-
vent contacting the Negative / Plasma or Pilot
Leads.

6. Remove the top nut and washer from the Pilot

Stud.

7. Place the lug on the Pilot Control Wire onto the

stud and secure with the nut and washer removed
in the above Step.

8. Tighten the Strain Relief onto the Torch Leads.

9. Check the torch for proper parts assembly per the

torch manual.

CAUTION

The torch parts must correspond with the type of

operation. Refer to Section 4.04-A, Torch Parts
Selection.

10. Reinstall the Power Supply Cover on the Power

Supply.

C. Remote Pendant Control (Optional)

In machine type operations the Power Supply has an
Adapter that has a cable connector supplied at each
end of the Adapter. One end is connected at the fac-
tory to the mating connector on the Power Supply
Bulkhead area. The other end allows connection of a
Remote Pendant. The remote pendant lead connec-
tor allows connection to a remote pendant or CNC
cable while using Control (PIP) Circuit connections
in the Torch Assembly.

Connect the remote pendant control cable to the con-
nector provided on the Adapter from the Power Sup-
ply.

NOTE

Refer to Appendix 3, Torch Control Cable Wiring
Diagram For Mechanized Systems, for detailed
schematic of the Adapter.