03 input wiring specifications, Input wiring specifications -2, Cutskill 35a – Tweco 35A CutSkill User Manual

Page 12

Advertising
background image

cutskill 35A

INTRODUCTION 2-2 Manual 0-5104

26lb / 11.8kg

5 1/4"

133 mm

16 1/2"

419 mm

RUN

SET

CURRENT (A)

25

35

READY

AIR

OVERHEAT

POWER

11"

280 mm

Art # A-09174

Figure 2-1 Power Supply Dimensions & Weight

NOTE

Weight includes torch & leads, input power cord, and work cable with clamp.

CAUTION

Provide clearance for proper air flow through the power supply. Operation without proper air flow will

inhibit proper cooling and reduce duty cycle.

2.03 Input Wiring Specifications

CutSkill 35A Input Power Requirements

Input

Power Input Current Input Current Input Suggested Sizes

(See Note)

Voltage

Freq.

(kVA)

Max (Amps)

Ieff (Amps)

Fuse (Amps)

(Volts)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

240

50

3.4

27.3

14

20

Line Voltages with Suggested Circuit Protection.
Motor start fuses or thermal circuit breakers are recommended for this application. Check

local requirements for your situation in this regard.

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).