background image

Installation

3-2

Manual 0-4686

4. Connect the cord to the input power terminal block

as shown for single or three phase. Input connec-
tions must be connected oposite the red and the
black wires. The white wire is used for 3 Phase.
Check for secure connections to the block. All cord
installations require a ground wire connection to the
power supply chassis; refer to the power supply
upper horizontal panel for proper ground wire con-
nection location.

Art # A-04670-S

Negro

Blanco

Rojo

NO SE
USA

Energía

de Entrada

Monofásico,
1 alambre

Art # A-04697

Black

White

Red

1 Phase
3 Wire

Input P

ow

er

Art # A-04652

Black

White

Red

3 Phase

Input P

ow

er

5. Provide a small amount of slack in the cord between

the terminal block and the through-hole protector.
Tighten the through-hole protector to the cord by
hand only. Do not overtighten or use a wrench.

For 230-Volt or 460-Volt Power Supplies Only:

6. Locate the input power bus bar block on the right

side of the power supply. Position the bars accord-
ing to the input power in use.

460V Input Power

230V Input Power

Bus Bars

Bus Bars

Ar

t # A-04650

7. Reinstall the power supply covers. Tighten the hard-

ware securely; do not overtighten.

Advertising