03 compressed air connection, 04 torch – Tweco C-100A CutSkill User Manual

Page 19

Advertising
background image

Manual 0-4686

3-3

Installation

3.03 Compressed Air Connection

• An air compressor is required and should be con-

nected by an air hose to the air regulator on the
rear panel of the power supply .

• Air flow should be 400 scfh / 6.6 scfm (188.7 lpm)

minimum.

Input Power
Cable

Connect
Air Here

Art # A-04489

3.04 Torch

• Make sure that the torch cable and torch switch

terminals are connected through the front panel.

• Make sure the Work Cable is connected properly

through the front panel and the clamp to clean
work surface.

• Before activating, turn torch away from yourself

and others.

DANGER

Do not cut in humid or wet surroundings.

• Before you maintain or replace torch parts, wait

for the post flow air cycle (approximately 10 sec-
onds), to stop, then turn the machine off.

• Always use original manufacturers parts. The use

of aftermarket parts could result in lower parts
life and in unsatisfactory cutting results. Any
warranty claims would be waived.

• Recycle worn parts according to local require-

ments.

NOTE

Repairs must be done by skilled and qualified
personnel only.

Advertising