Section 4: operation, 01 front control panel – Tweco C-100A CutSkill User Manual

Page 21

Advertising
background image

Manual 0-4686

4-1

Operation

SECTION 4:

OPERATION

4.01 Front Control Panel

I

O

100A

100A

A

30

40

70

50

60

100

80

90

Overheating
Indicator

AC Power
Indicator

Air Error Indicator

Torch Latch
Switch Indicator

Torch Latch
Switch

Air Set
Switch

Air Vents

Work Lead

"On / Off"
Switch

Torch

Current Control
Knob

Art # A-04483

A. Indicator Lamp

• Power Indicator

Lights when primary power switch is turned
on.

• TEMPERATURE Indicator

Indicator is normally OFF. Indicator is ON
when internal temperature exceeds normal
limits.

• Air Error Indicator

This indicator lights when there is not enough
air pressure to operate the power supply.

NOTE

It is possible to have enough air pressure to op-
erate the power supply but not enough air flow
to operate the torch.

• Torch Latch Switch Indicator

This indicator lights when the Torch Latch
Switch has been pressed for continuous cut-
ting.

B. Switches

• Torch Latch Switch

For continuous cutting performance. Depress
this switch ( turn “On” ) while cutting with the
torch. Release the torch trigger and the torch
will continue to cut without depressing the torch
trigger.

• Air Set Switch

To check for proper air setting and to cool down
heated torch.

C. Main Current Control Knob

To adjust cutting current. Turning clockwise in-
creases the cutting current and counter clock-
wise decreases the cutting current.

30

40

70

50

60

100

A

Art # A-04484

80

90

D. Primary Power Switch, ON / OFF

The power switch is located on the front panel.
Placing the primary power switch to the “ON”
position energizes the power source.

WARNING

When the power source is overloaded, the switch
turns to the OFF position automatically. DO
NOT TURN ON BY FORCE.