SECTION 3: INSTALLATION PROCEDURES

12

Manual 0-2784

• If using a fork lift vehicle, place and secure unit on a

proper skid before transporting.

• This unit has a handle mounted on top of the enclo-

sure for hand lifting only. Be sure unit is lifted and
transported safely and securely.

WARNING

HANDLE

is not for mechanical lifting.

3.05 Input Power Cable Connections

The 100XL PLUS Power Supply (CE) operates on three
phase, 380/415VAC, ± 10% 50/60Hz input.

CAUTION

The primary power source,power cable must all
conform to local electric code and the recommended
circuit protection and wiring requirements (refer
to table in Appendix I).

The Power Supply is supplied with a three-phase, four
conductor, input EMC power cable attached. Connect
the supplied input EMC power cable to the customer's
power source per the following procedure:

NOTE

The input power cable must not be modified in any
way as filtering beads are installed on the cable.

1. Strip back the outer covering approximately 3

inches (76 mm) to expose the individual wires at
the free end of the cable.

2. Cut back the insulation on the individual wires

approximately 1/8 - 3/16 inch (3-5 mm).

3. Connect the ends of the individual wires a cus-

tomer supplied plug or main disconnect per the
following:

NOTE

All the input cable wires must be connected for
three-phase operation.

• Blue wire to Line 2 (Live)

• Black wire to Line 3 (Live), refer to Note above

• Brown wire to Line 1 (Live)

• Green/Yellow wire to Ground (Earth)

3.06 Gas Connections

A. Gas Requirements

WARNING

This unit not to be used with oxygen (O

2

).

Gases: Compressed Air or Nitrogen (N

2

) Only

Pressure: 70 psi (4.8 bar)

CAUTION

Maximum input gas pressure must not exceed 125
psi (8.6 bar)

Flow:

Cutting - 400 scfh (188.7 lpm)

Gouging - 400 scfh (188.7 lpm)

B. Checking Air Quality

To test the quality of air, place the RUN/SET/LATCH
switch to SET position, place a welding filter lens in front
of the torch and turn on the gas. Any oil or moisture in
the air will be visible on the lens. Do not initiate an arc!

CAUTION

Air supply must be free of moisture, and other con-
taminants. Excessive and moisture may cause
double-arcing, rapid tip wear, or even complete
torch failure. Contaminants may cause poor cut-
ting performance and rapid electrode wear.

C. Gas Connections

The gas supply is connected to the Pressure Regulator/
Filter Assembly installed on the rear of the unit. The con-
nection is the same for compressed air or high pressure
gas cylinders.

1. Locate the 1/4 NPT to #4 (6mm) hose barbed fitting

shipped inside the Torch Spare Parts Kit.

2. If an optional air line filter is to be installed, refer to

subsection D.

NOTE

Filtering is required when using air from a com-
pressor to insure that moisture and debris from the
supply hose does not enter the torch. We recom-
mend either the optional Dry Air Filter Kit or Two
Stage Filter Assembly to provide the necessary fil-
tering.