09 tip saver/drag cut sensing circuit – Tweco PakMaster 100XL Plus User Manual
Page 22
Advertising
SECTION 3: INSTALLATION PROCEDURES
16
Manual 0-2784
3.09 Tip Saver/Drag Cut Sensing
Circuit
This power supply is equipped with a Tip Saver/Drag
Cut Sensing Circuit which reduces current to 35 amps if
the tip touches the workpiece in order to to prolong the
life of the tip.
If the user does not want the current to be decreased when
the tip touches the workpiece, the sensing circuit can be
defeated by closing switch SW1-1 on the Gate/Logic PC
Board. Slide top white toggle on SW1-1 to the right to
close circuit.
A-02569
Gate/Logic PC Board
SW1
1 2
ON
Figure 3-9 SW1 Switch Location
WARNING
Tip life will be considerably shortened if tip is re-
peatedly touched to the workpiece without the Tip
Saver/Drag Sensing Circuit feature active.
Advertising