04 troubleshooting guide – Tweco PakMaster 100XL Plus User Manual

Page 31

Advertising
background image

Manual 0-2784

25

SECTION 5: SERVICE

Dross present on top of the plate (top spatter), is normally
caused by a slow torch travel speed or too high of a torch
standoff distance.

F. Common Cutting Faults

1. Insufficient Penetration

a. Cutting speed too fast

b. Torch tilted too much

c. Metal too thick

d. Worn torch parts

e. Cutting current too low

2. Main Arc Extinguishes

a. Cutting speed too slow

b. Torch standoff too high from workpiece

c. Cutting current too high

d. Work cable disconnected

e. Worn torch parts

3. Excessive Dross Formation

a. Cutting speed too slow

b. Torch standoff too high from workpiece

c. Worn torch parts

d. Improper cutting current

4. Short Torch Parts Life

a. Oil or moisture in air source

b. Exceeding system capability (material too thick)

c. Excessive pilot arc time

d. Air flow too low (incorrect pressure)

e. Improperly assembled torch

5.04 Troubleshooting Guide

A. General

Troubleshooting and repairing this unit is a process which
should be undertaken only by those familiar with high
voltage high power electronic equipment.

WARNING

There are extremely dangerous voltage and power
levels present inside this unit. Do not attempt to
diagnose or repair unless you have had training in
power electronics measurement and troubleshoot-
ing techniques.

B. Basic Troubleshooting

This manual covers a basic level of troubleshooting that
requires limited dissasembly and measurements. It is
helpful for solving many of the common problems that
can arise with this system.

If major complex subassemblies are faulty, the unit must
be returned to an authorized service center for repair.

Follow all instructions as listed and complete each sec-
tion in the order presented.

For major troubleshooting and parts replacement pro-
cedures refer to PAK Master 100XL PLUS Power Sup-
ply (CE) Service Manual 0-2785.

C. How to Use This Guide

The following information is a guide to help the Cus-
tomer/Operator determine the most likely causes for
various symptoms.

This guide is set up in the following manner:

X. Symptom (Bold Type)

Any Special Instructions (Text Type)

1. Cause (Italic Type)

a. Check/Remedy (Text Type)

Locate your symptom, check the causes (easiest listed first)
then remedies. Repair as needed being sure to verify that
unit is fully operational after any repairs.

A. Main power line fuses blow as soon as main

disconnect is closed

1. Input power cable not properly connected to customer's

main power panel

a. Check that input power cable is properly con-

nected (refer to Section 3.05, Input Power Con-
nections)

Advertising