INSTALLATION PROCEDURES

3-2

Manual 0-2556

The Standoff Control Assembly and external cable instal-
lation is the same for all systems.

3.05 Mounting Bracket Assembly

Installation

The Mounting Bracket Assembly is used to mount the
Standoff Control Assembly and must be installed in a suit-
able location where it is easily accessable to the system
operator. The unit can be mounted on top of or under-
neath a mounting surface.

Install the Mounting Bracket Assembly per the following
procedure:

1. Select the mounting surface for the Mounting Bracket.

2. Mount the bracket to the surface either on top of or

underneath the surface using four 1/4" bolts (not sup-
plied). It is recommended to use at least four bolts to
mount the bracket but a minimum of two are required.

NOTE

There are seven holes provided in the Mounting
Bracket. Use any four holes that are convenient
for the application.

1/4" Mounting Bolts

(Not Supplied)

Mounting Holes

(Seven Places)

A-00671

Figure 3-1 Bracket Mounting On Top Of Surface

A-00672

1/4" Mounting Bolts

(Not Supplied)

Mounting Holes

(Seven Places)

Figure 3-2 Bracket Mounting Underneath Surface

3.06 Standoff Control Assembly

Installation

Mount the Standoff Control Assembly per the following
procedure:

1. Install the Mounting Bracket per Section 3.05.

2. Insert two of the #10-32 x 3/8" hex head bolts into the

slots on each side of the Standoff Control unit. The
slot prevents the bolts from turning when the knobs
are installed.

Slot

Hex Head Bolt

#10-32 x 3/8"

Knob

A-00688

UP

DN

TORCH

TORCH

Figure 3-3 Bolt Installation

3. Set the Standoff Control unit into the Mounting

Bracket being sure the four bolts are in the mounting
slots.

Advertising