09 external cable connections, 09 external cable connections -5 – Tweco SC11 User Manual

Page 21

Advertising
background image

Manual 0-2556

3-5

INSTALLATION PROCEDURES

Standoff Control

PC Board Assembly

A-01424

J11

E1

Pin 6

Pin 7

Figure 3-8 Motion (OK-To-Move) Jumper Location

A jumper wire is connected between the terminal block
J11 pin 7 and the lug connection E1 on the PC board. Se-
lect the proper operation by moving the end of the wire
connected to the terminal block per the following chart:

M o t io n (O K-T o -M o ve ) Se le ct io n

J1 1

C o n t a ct s o r E xt e rn a l 1 1 5 V

6

2 4 V AC

7 *

* = F a ct o ry Se t t in g

3.09 External Cable Connections

There are four standard output connectors and one strain
relief at the rear panel of the unit. Connect the required
control cables per the following:

A-00693

MOTOR

J43

Lifter Motor

Control Cable

PLASMA

J42

EXTERNAL

POWER

J41

CNC

J40

CNC

Strain Relief

CNC Control

Cable

External Input

Power Cable

Plasma Power

Supply Control

Cable

Figure 3-9 Cable Connections

1. Lifter Motor Cable

Connect the Lifter Motor Control Cable to the rear
panel of the Standoff Control to the receptacle marked
J43 (MOTOR). The other end of the cable is connected
to the lifter motor equipment.

2. Power Supply Control Cable

Connect the Power Supply Control Cable to the rear
panel of the Standoff Control to the receptacle marked
J42 (PLASMA). Connect the other end of the cable to
the Power Supply receptacle marked TO REMOTE
CONTROL. Power Supply connector is J22 on Mer-
lin 1000 Systems.

NOTE

Some systems may supply the +48 volts external
power from the Plasma Power Supply via the Con-
trol Cable. These Remote Cables have two connec-
tors for PLASMA (J42) and EXTERNAL POWER
(J41).

3. External +48 Volt Power Source

Connect the External Power Source Cable to the rear
panel of the Standoff Control to the receptacle marked
J41 (EXTERNAL POWER). The other end of the cable
is connected to the external +48 volt power source.
The factory supplied external power source can be
connected to 115 or 220 VAC, 50/60Hz.

NOTE

Plasma Power Supplies that do not have a +48 volt
output require a seperate external power source.