Operation

3-2

Manual No 0-0470

10

13

15

14

11

12

16

VOLTS

D.C.

100

200

300 400

500

AMPERES

D.C.

100

200

300 400

500

AC POWER

1FU

2FU

3FU

4FU

HI-FLOW

WATER SHIELD

ON

OFF

DC POWER

PILOT

AUTO

MAN

SURFACE

UNDERWATER

DO NOT SWITCH

UNDER LOAD

Figure 3-B TA-500 Power Supply Front Panel

10. AC POWER Indicator

Red light indicates that Primary AC power is be-
ing supplied to the Power Supply.

NOTE: Fan should be running when this light is
on.

11. DC POWER Indicator

Red light indicates that main contactor (W) has
closed to supply current to the main bridge recti-
fier and that cutting current is available.

12. PILOT AUTO/MAN Switch (SW9)

With the switch in the MAN position the pilot arc
will start two seconds after the green START but-
ton is pressed and will stay on for 2 seconds only.
The main cutting arc must transfer in this time. If
the pilot arc goes out press the red STOP button,
and the green START button to recycle the torch.
The torch must be recycled after each cut to start
the pilot arc again. In the AUTO position the pilot
arc will remain on until the cutting arc is transferred
and will restart when the cutting arc goes out.

13. SURFACE/UNDERWATER Switch (SW8)

Selects the proper resistance value of the pilot re-
sistor for the type of cutting operation.

NOTE: Do not switch under load.

14. HI-FLOW WATER SHIELD ON/OFF Switch (SW8)

The ON position activates the circuitry for the hi-Flow
Water shield (optional) control. The OFF position deac-
tivates the circuit.

15. Voltmeter

Indicates the voltage between the torch electrode
and the workpiece (voltage on main bridge recti-
fier). Useful in troubleshooting.

16. Ammeter

Indicates amount of cutting current being supplied
from the Power Supply to the torch.

19

17

18

20

21

PLASMA

SECONDARY

COOLANT

WATER

SHIELD

GAS

Figure 3-C Supply Console Front Panel

17. PLASMA Gauge

Indicates pressure at which plasma gas is being sup-
plied to the torch.

18. SECONDARY Gauge

Indicates pressure at which secondary gas is being
supplied to the torch.

19. SECONDARY Flowmeter

Indicates flow rate at which secondary water is
being supplied to torch.

20. GAS/WATER SHIELD Switch (SW7)

Used to select either gas or water as a secondary.

21. COOLANT Gauge

Indicates pressure at which coolant is supplied to
the torch.